12
Enable DHW programming
Follow the instructions given below to enable domestic hot water programming.
1. Keep the button pressed for 3 seconds.
2. The display shows the CU parameter.
3. Press the button twice.
4. The display shows parameter P1.
Set to 0 using the buttons to disable domestic hot water programming. Set to 1 using the
buttons
to enable domestic hot water programming.
5. Press any other button to exit the menu.
To set the weekly automatic programme proceed as described in the section “Step 2. Automatic weekly
programme setting”, selecting the tap symbol at step “1” and setting EC (Economy) or CO (Comfort) at step
“3” rather than a temperature value. In fact the remote control has a weekly time programmer based on two
levels: during the COMFORT level, the boiler will maintain the set hot water tank temperature; during the
ECO level, the boiler will not deliver domestic hot water. Refer to the boiler documentation for information
on the type of hot water storage tank.
Important: Make sure the remote control is set to Winter mode with automatic operation
Pre-heating Function
This function is active only if the automatic heating mode has been selected. When set to Automatic, the
function anticipates the heating system start time (not before 00:00 hours on the same day) so that the
room temperature set by the user is reached at the start of the programmed time band. The Remote Control
calculates an initial hypothetical Pre-activation time: if the programmed room temperature is reached in a
shorter time than that calculated, the Pre-Heating time will be decreased, and vice versa. This creates a
self-learning process, for identifying the minimum necessary Pre-activation time.
The Remote control also offers also the possibility of setting a fixed Pre-Heating slope: In this case, the
room temperature will be increase by 3°C an hour. Therefore the automatic heating programme should
be set according to the time when heat is required and not that when the heating system is to be started.
Follow the instructions given below to activate or deactivate this function.
1. Keep the button pressed for 3 seconds
2. The display shows the CU parameter.
3. Press the button 3 times.
4. The display shows parameter P2.
Set to 0 using the buttons
to deactivate Pre-Heating.
Set to 1 using the buttons
to activate Automatic Pre-Heating
Set to 2 using the buttons
to activate Pre-Heating. Set to 2 using the butons to activate
the Pre-Heating function with a fixed slope of 3°C per hours.
5. Press any other button to exit the menu.
During the preheating function the room temperature °C symbols flashes
The pre-heating function ends when the difference between the programmed room temperature and the
actual room temperature is less than 0.5 °C.