16
Installation info
Diaphragm
Neoprene
gasket
fig. 14
Deflector
EXAMPLE WITH THE AIR SUCTION DUCT ON THE L.H. SIDE
From
ΔΔΔΔΔ
P=15 up to
ΔΔΔΔΔ
P=30 Pa
2.2.8 - SMOKE EVACUATION
THROUGH TWO SEPARATE
DUCTS Ø 80
(Type B accessories)
NB:
The maximum allowed pressure
drop, according to the installation
type, must be equal to the value
indicated in the installation
examples given on page 17.
For installations with smoke
evacuation through separate
ducts, whose pressure drop value
is between 15 Pa and 30 Pa, it is
necessary to fit a diaphragm,
supplied with the boiler, inside the
smoke outlet (see fig. 13 or fig. 14).
It is necessary to place the
eflctor inside the air suction duct.
Diaphragm
Neoprene
gasket
fig. 13
EXAMPLE WITH THE AIR SUCTION DUCT ON THE R.H. SIDE
Deflector
Diaphragm
From
ΔΔΔΔΔ
P=15 up to
ΔΔΔΔΔ
P=30 Pa