37
Instruction for the installer
3.20 - VARIATION OF OUTPUT RANGE
It is possible to adjust the maximum input by reducing the fan
speed.
Output range
Maximum imput
Parameter FHCH (rpm x 100)
ALKON R 35 HE - C 35 HE
0
2
4
6
8
01 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
ALKON R 28 HE - C 28 HE
0
2
4
6
8
01 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Output range
Maximum imput
Parameter FHCH (rpm x 100)
With the “Regolafacile” parameter FHCH:
rpm x 100 ex. 70 = 7000 rpm
For example: with the parameter FHCH settled on 54, the
correspondent maximum input will be of 28 kW.