3.18 - PARAMETERS WHICH CAN BE
MODIFIED FROM PANEL BOARD
WARNING!
Function reserved exclusively to the
Authorized Service Centres!
Some of the service parameters can be modified
from the panel board:
- PUMP OVERRUN
0
=
5 min
1
=
Continuous operation
Factory setting:
0
- OUTER SENSOR TEMPERATURE
ADJUSTMENT
Possible setting from
0
(-20°C)
to
30
(+10°C)
Factory setting:
20
(0°C)
- NIGHT REDUCTION
Desired value
0
(DISABLED)
Possible setting from
0°C
to
30°C
(ENABLED)
Factory setting:
0
- ENABLING/DISABLING
ECO / COMFORT
0 = OFF 1=ON
Factory setting:
1
- MAXIMUM HEATING OUTPUT
ADJUSTMENT
Possible setting from
0
to
99
Factory setting:
99
B
D
C
E
°C
°C
°C
°C
°C
To enter the parameters push and keep
pressed for ten seconds the reset button
(release when the flashing wrench appe-
ars on the display).
MAX
M
IN
Rotate the HEATING temperature
adjustment knob “
B
” to select the
parameter which needs to be changed:
Po
-
°C
–
nr
–
PH
–
HP
; the parameters are
shown on the display “E”.
Confirm the parameter to be changed by
pressing the reset button.
Modify the value of the parameter
previously selected by rotating the D.H.W.
temperature adjustment knob “
C
”. The
new value flashes on the display.
Modify the value of the parameter
previously selected by rotating the D.H.W.
temperature adjustment knob “
C
”. The
new value flashes on the display.
Store the new value of the parameter by
pushing the reset button.
To exit from parameter list wait 20 s or
rotate quickly the D.H.W. temperature
adjustment knob “
C
”.
°C
MAX
M
IN
MAX
F
G
L
I
M