11
“FIRE ON”
The stove is in the flame stabilisation phase (flame present).
“ON 1”
The stove is in the work phase at the minimum output. The detected room temperature is
29°C.
“ECO”
The stove has reached the temperature set by the user and is in the economy phase. The
output cannot be changed in this phase.
If the temperature is set at 41°C, the stove keeps operating at the set work output without
switching to economy mode (ECO).
“STOP FIRE”
The stove is in the basket self-cleaning phase; the flue gas extractor fan runs at maximum
speed and pellet loading is at minimum (parameter not editable).
5.1 Particular cases
The set temperature must be higher than the temperature detected by the room tempera-
ture probe (+/-1°C). Otherwise the text “ON T” will appear. In this case, to switch on the
stove, set the temperature at least 4°C higher than the one shown on the display.
If the display still reads “ON T”, contact the Authorised Service Centre. Pressing the key
restarts the stove with the previously set parameters.
“SERV” ALARM
When the text “serv” appears, it means the stove has reached 900 working hours. Contact
the Authorised Service Centre for maintenance.
“ALARM NO ACC”
: failed ignition
This is triggered when after the ignition period of approximately 15 min. the flue gas
temperature is still insufficient. It can also occur when there is a low amount of pellets at
ignition.
“DEP FAIL”
: obstruction in flue gas exhaust pipes
Make sure the flue has no obstructions or excessive filth.
In case of a power failure (even a few seconds), the stove switches off.
The display will read
COOL FIRE
and the stove will restart after having performed a cool
-
ing cycle.
“FAN - ACC”
The stove is in the resistance preheating phase prior to ignition.
“LOAD WOOD”
Indicates that the stove is in the pellet loading phase.