Installation instructions
FLOOR-CEILING INSTALLATION
CHOICE OF THE INSTALLATION SITE FOR THE INTERIOR UNIT
Positions to avoid:
· Places in direct sunlight.
· Positions near heat sources.
· Damp places and positions where the unit could come into contact with water (e.g.: washrooms).
· Places where shelves or furniture could prevent the air from circulating correctly.
What to do:
· Choose a position without obstructions that could hamper the air inlets and outlets.
· Choose a position where the appliance is easy to install.
· Choose a position that complies with the recommended minimum space for maintenance work.
· Choose a position that allows air to freely circulate around the room.
· Install the appliance so that the condensation can be easily drained off.
· Choose a position possibly in the middle of the room. Adjustment of the outlet air can then be optimized to reach all
parts of the room.
· The best position for the fins is usually the one that allows the air to blow on to the ceiling through the Coanda effect.
· Check to make sure that the chosen position allows the panels to be sufficiently removed from the ceiling to allow
the installation and maintenance operations to be carried out.
· Do not install the appliance where water can drip on to it.
Place
• Install it on a rigid, vibration-free wall and then level it.
• Remove any obstructions from in front of the air inlet and outlet gril-
les.
• Keep well away from gas sources, inflammable liquids and from
acid or alkaline substances.
• Do not expose the internal unit to direct sunlight.
• Install in a place where it is easy to connect to the exterior unit.
• Make sure that the condensation can flow away easily.
• Move the pipes or power cable near.
• Allow sufficient space for easy maintenance, as shown below.
• Install the interior unit well away from heat or steam sources.
• Do not install the air conditioner in places where there are vapours
or heavy oily gases.
• Install the interior unit in a place where the cold air can be distri-
buted to all parts of the room.
• Set the interior unit at least one meter away from televisions,
radios, appliances operated with remote controls and flourescent
lamps.
• Respect the minimum distances to ensure proper installation and
sufficient access for maintenance.
Summary of Contents for MFX2 18 HE
Page 11: ...11 Istruzioni di installazione MFX4 28HE MFX2 24HE...
Page 12: ...12 MFX5 42HE MFX4 36HE...
Page 45: ...45 Installation instructions MFX4 28HE MFX2 24HE...
Page 46: ...46 Installation instructions MFX5 42HE MFX4 36HE...
Page 70: ...70 Installation instructions...
Page 71: ...71...