background image

Unibor EQ35 Manual 

                   Original instructions 

               Apr 2020 

18 

 

 

 

17) WARRANTY STATEMENT 

 

 

Unibor

 warrants its machines to be free from faulty parts, under normal usage of machines, for a period of 

12 months from initial date of purchase. All other parts (excluding cutters) are under warranty for 90 days, 
provided that the warranty registration card (or online registration) has been completed and returned to 
Unibor

™ 

or its designated distributor within a period of (30) days from the purchase date.  Failure to do so 

will void the warranty. If the stated is adhered to, Unibor

™ 

will repair or replace (at its option) without 

charge any faulty items returned.

 

 

This Warranty does not cover: 

1.

 

Components that are subject to natural wear and tear caused by the use is not in accordance with the 

operator’s instructions

 

2.

 

Defects in the tool caused by non-compliance with the operating instructions, improper use, abnormal 
environment conditions, inappropriate operating conditions overload or insufficient servicing or 
maintenance. 

3.

 

Defects caused by using accessories, components or spare parts other than original 

Unibor

™ 

parts. 

4.

 

Tools to which changes or additions have been made. 

5.

 

Electrical components are subject to manufacturer’s warranty.

 

 
 
The warranty claim must be logged within the warranty period. This requires the submission or sending of 
the complete tool in question with the original sales receipt which must indicate the purchase date of the 
product. A complaint form must also be submitted prior to the return. 
Failure to complete this form will result in the delay of your claim. 
All goods returned defective must be returned pre-paid to Unibor

, in no event shall Unibor

 be liable for 

subsequent direct, or indirect loss or damage. 

 

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, (EXPRESSED OR IMPLIED) INCLUDING ANY 

WARRANTY OF MERCHANTABLITY OR FITNESS FOR A PURPOSE. UNIBOR

RESERVE THE RIGHT TO MAKE 

IMPROVEMENTS AND MODIFICATIONS TO DESIGN WITHOUT PRIOR NOTICE 

 

Known and Trusted Worldwide for Quality, Performance and Reliability

 

 

Summary of Contents for EQ35

Page 1: ...Unibor EQ35 Manual Original instructions Apr 2020 1 Magnetic drilling machine Model Number EQ35 Serial Number Website www unibor com...

Page 2: ...cedures Operating instructions Extension cable selection Mounting of cutters Remedies for hole making problems Wiring diagram Exploded view Motor Breakdown Control panel and parts List Maintenance Tro...

Page 3: ...ipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose power tools to rain or wet conditions Water entering a power tool will inc...

Page 4: ...ind and are easier to control 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before...

Page 5: ...h 7 43 64 Length Overall 8 55 64 Nett Weight 26 4 lbs Vibration total values triax vector sum in accordance with EN60745 Vibration emission value a W 1 67 m s Uncertainty K 1 5m s Level of sound press...

Page 6: ...from the arbor If the machine is accidentally dropped ALWAYS thoroughly examine the machine for signs of damage and check that it functions correctly BEFORE resuming drilling Regularly inspect the mac...

Page 7: ...is necessary this must be done by the manufacturer or an approved agent in order to avoid a safety hazard Assuming a normal AC supply of the correct voltage it is recommended that the following exten...

Page 8: ...service is available Improve centre punch and or replace worn parts Replace part or parts 3 Excessive drilling pressure required Incorrectly re sharpened worn or chipped cutter Coming down on swarf l...

Page 9: ...Unibor EQ35 Manual Original instructions Apr 2020 9 10 WIRING DIAGRAM Standard Wiring Diagram MLC Wiring Diagram...

Page 10: ...Unibor EQ35 Manual Original instructions Apr 2020 10 11 EXPLODED VIEW OF MACHINE...

Page 11: ...13 SELPIN410 4 x 10 SELOC PIN 2 14 M0831 RACK 1 15 SC516CAP M5 X 16 CAP HEAD SCREW 1 16 10076 OIL CUP RET CLIP 1 17 10085B M5 NYLOC 1 18 10085A M5X25 KNURLED POINT GRUB SCREW 5 19 10085B M5 NYLOC 5 20...

Page 12: ...Unibor EQ35 Manual Original instructions Apr 2020 12 12 MOTOR BREAKDOWN 14...

Page 13: ...V 1 12 EIB038 S TAPPING SCREW C3 9X60 2 13 EIB176 FAN COVER 1 14 EIB177 GEAR PLATE 1 16 UDC009 BEARING 608 2 17 EIB179 LOCATING DOWEL 1 18 EIB039 CIRCLIP 10 1 1 19 EIB181 GEARBOX SEAL 1 20 EIB023 SPUR...

Page 14: ...Apr 2020 14 13 CONTROL PANEL AND PARTS LIST No Item Description Qty 1 NCP12 NCP SWITCH PLATE MED UNIBOR 3 COLOUR 1 2 NCP001 DRILL STOP START SWITCH 120V 1 3 NCP006 MAGNET SWITCH NCP PANEL B418CG00000...

Page 15: ...ust be checked to ensure that all components are working correctly Machine Brushes should be checked to make sure there is no abnormal wear present this should be checked at least once a week if used...

Page 16: ...sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged Field burned Carbon brushes worn out Motor does n...

Page 17: ...Steel angle and joists 700N mm M2 Steel angle and joists 850N mm M42 Plate and sheet steel 700N mm M2 Plate and sheet steel 850N mm M42 Aluminium 750Nmm M2 Aluminium 850N mm M42 Brass 700N mm M2 Brass...

Page 18: ...ditions inappropriate operating conditions overload or insufficient servicing or maintenance 3 Defects caused by using accessories components or spare parts other than original Unibor parts 4 Tools to...