15
Lubrication table
Lubrication point
No.
Fig.
8-2
Component
No. of lubrication
points
Type of lubricant
Interval
Notes
1
2
3
4
5
6
1
Lift axle
1
ŁT
-41
every 50h
through grease nipple
2
Fig.
7-1
Rear roller axle
2
ŁT
41
every 50h
through grease nipple
3
Cylinder heads
2
ŁT
41
every 50h
through grease nipple
4
Cylinder piston rod
1
ŁT
-41
every 50h
on the surface
5
PTO drive shaft
1
Acc. to PTO instructions
Bevel gear (7)
The gear is filled with HIPOL 15 or GL 4 gear oil in
an amount of 5 liters (4.5 kg).
Change the oil with a new one after purchasing a new machine and after 50 hours of its
operation.
Then, the oil should be changed every 500 hours of operation.
Cylindrical gear
–
bath
(6).
Checking the oil level in the cylindrical gear (bath) takes place with the oil filler cap, on which the dip rod
is mounted. After inserting the oil cap with the dip rod into the filler hole, the oil should be at a height
between 10-15 mm from the bottom edge of the dip rod, indicating a sufficient oil level. Screw the cap
to the stop
after checking the level.
Check the lubricant level once a week
.
Check the grease level
by placing the unit in the horizontal plane.
If the oil level is too low, top up with CLP 460 oil that the bath is filled with.
7. Settings and Adjustments
7.1.
Adjustment of
the Vertical Position
HERMES cultivator unit must be perpendicular to the ground during operation. Mount the unit on the
tractor before the adjustment and lower it into the working position on a flat and hard surface.
Adjustment is carried out using the adjusting screw (1), Fig.9-1, connecting the top point of the tractor
three-point system with the upper point of the machine hitch.
Fig.
Fig.8-2
drain
Fig.9-1
Fig.9-2
Fig.9-3
Fig.9-4
Summary of Contents for HERMES 3.0
Page 2: ...2 ...
Page 22: ...22 UWAGI I NOTATKI ...