OPERATING AND MAINTENANCE MANUAL ARES L
- 28 -
The service is limited to control the tightness of the system and replacing elements that bear
traces of mechanical damage. At least twice a year, and especially before winter, you should
dewater the pneumatic system. To do this, unscrew the plug
[1]
Fig. 20 in the lower part of
the air tank
[2]
Fig. 20 by 3 to 4 turns. This will squeeze the water collected in the tank. After
removing the water, the plug must be re-tightened and the installation checked for leaks.
Fig. 23.
Dewatering of the pneumatic brake system
3.5.10 Seeder support adjustment (hydropak option - ARES L 2.5; 3.0; 3.5; 4.0)
The seeder support can be adjusted in three
directions:
•
front-back:
unscrew the screws
[B],
set the appropriate position
of the base, adjust the screws and tighten them
•
up-down:
unscrew the screws
[A],
set the appropriate position
of the base, tighten the screws
•
tilt angle
loosen the bottom screw
[C]
, unscrew and remove
the screw
[D]
, set the appropriate angle of support
inclination, adjust the screws
[D]
to the holes
[F]
,
tighten the screws
Fig. 24.
Seeder support adjustment
3.5.11 Support wheel adjustment (option)
The support wheel
[A]
can be adjusted using the
turnbuckle
[B].
Rotate the turnbuckle so that the
support wheel will get up or down.
Fig. 25.
Support wheel adjustment ARES L
4.5;6.0 (option)