Operating and mounting manual
(translation)
EV / EVF
_______________________________________________________________________________________________________
220.100.091-05
Page 11 /21
Version: 06/2017
TM 4474
NOTICE!
For special application such as for oxygen use only the approved Lubricants
Assemble the valve in the reverse order to the dismantling.
CAUTION!
Install wear parts carefully and properly and do not damage them during assembly.
Examine the valve for internal and external leaks and finally carry out a function test.
9.0 Warranty
Scope and period of the warranty is specified in the edition of the “General Terms of Business of the
UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH” valid at the time of delivery or else in the
purchase agreement.
We warranty that the valve is free from faults in line with the state of the art and for the confirmed field
of application.
No warranty claims will be accepted for damage resulting from improper use or failure to observe
these operating and installation instructions, the statutory accident prevention regulations, the EN, DIN
and VDE standards and other codes and regulations.
Warranty claims will also not be accepted for damage occurring during operation due to operating
conditions deviating from those specified in the data sheet or in other agreements.
Justified complaints will be remedied by reworking by us or specialist companies authorised by us.
Claims going beyond the scope of the warranty will not be accepted. The customer shall have no right
to the supply of a replacement valve.
Maintenance work, installation of parts from other manufacturers, any modifications to the design and
natural wear are not covered by the warranty.
Transport damage must be reported not to us but
without delay
to your responsible goods handling
company, the railway company or the shipping agent as otherwise all claims for damages against
these companies will be voided.
10.0 Explanations on Codes and Directives
The Council of the European Community has passed common guidelines for the free exchange of
goods within the Community; these guidelines determines a minimum of requirements for safety and
protection of health. The type test confirms that products correspond to the EC guidelines, i.e. are in
conformity with the relevant, especially harmonized standards. The directives DIN EN 264 refer to oil
solenoid valve (mechanical part).
Notes concerning directives DIN EN 264:
The valves must be developed, manufactured and checked under observation of standard DIN EN
264. This is proven by the type test.
Notes on Directive 2014/68/EU (Pressure Equipment Directive, DGRL):
It has been conformed that the quality assurance in design control, manufacture and final acceptance
of the manufacturer, UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH, satisfy the require-
ments of 2014/68/EU Article 14 Module H. The gas solenoid valves comply with the fundamental
requirements of Directive 2014/68/EU. Valves in according to Article 1 Paragraph 2,f,v or Article 4
paragraph 3 are not allowed to have the CE Mark in according to Article 18.