User’s Manual and UT5320R-SxA Series
27 / 43
Instruments.uni-trend.com
Step mode Normal
,
cycle
,
single
Normal
①
Normal: The normal test mode of the instrument.
②
Cycle: Automatic cycle after the file test is
finished.
③
Single: Only test the current step.
ResetClear OFF, ON
OFF
①
When the reset is enabled and the test is failed,
press [STOP] key and then press [START] key to
continue the test.
②
When the reset is disabled and the test is failed,
press [START] key to continue the test.
Ctrl mode
File
,
single step
File
①
File: When file test is finished, HANDLER interface
outputs the test result.
②
Single Step: After each step is finished, HANDLER
interface outputs the test result of the current
step.
Pass Hold
(0.1~99.9)s
,
key control
Key control
①
(0.1~99.9) s: When the test is qualified, hold time of
the qualified judgment.
②
Key control
:
When the test is qualified, and the
test is qualified, press [STOP] key to end.
Turn Mode OFF, ON
OFF
①
OFF
:
Output voltage cannot be change during the
test
②
ON
:
The size of output voltage can be fine tunning.