Note:To ensure measurement accuracy, operating temperature should be within 

18°C~ 28°C and the fluctuation range should be within #1°C.
Temperature <18°C or >28°C: Add temperature coefficient error 0.1 x (specified 

accuracy)/ °C.

Safety information

Do not use the meter if the rear cover is not covered up, or it will pose a shock hazard!
Before use, please check and make sure the insulation layer of the meter and test leads 

is in good condition without any damage or broken wires. If you find the insulation layer 

of the meter housing is significantly damaged, or if you think the meter cannot function 

properly, do not use the meter.
When using the meter, your fingers must be placed behind the finger guard ring of the 

test leads.
Do not apply voltage over 600V between any meter terminal and earth ground to prevent 

electric shock and damage to the meter.
Be cautious when the measured voltage is higher than 60V (DC) or 30Vrms (AC) to avoid 

electric shock!
The measured signal is not allowed to exceed the specified limit to prevent electric 

shock and damage to the meter!
The range switch should be placed in the corresponding position during measurement.
Never change the range setting when measuring to avoid damage to the meter!

ENGLISH

Do not change the internal circuit of the meter to avoid damage to the meter and user!
When the " " symbol appears on the LCD, please replace the batteries in time to 

ensure measurement accuracy.
Do not use or store the meter in high temperature and high humidity environments. The 

performance of the meter may be affected.
Clean the meter casing with a damp cloth and mild detergent. Do not use abrasives or 

solvents!
Measure known voltage with the meter to verify that the meter is working properly. If 

the meter is working abnormally, stop using it immediately. A protective device may be 

damaged.
If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.
If the test leads need to be replaced, you must use a new one which should meet EN 

61010-031 standard, rated CAT IlI 600V, 10A or better.

ENGLISH

Summary of Contents for UT123T

Page 1: ...manual EN SV NO XXXXXXXXX Art no 40727 2020 08 24 Box 50435 Malm Sweden Uni T...

Page 2: ...e AC voltage position Insert the red test lead into the jack black into the COM jack and make the probes in contact with both ends of the measured voltage parallel connection to the load Read the test...

Page 3: ...ully discharge all capacitors to avoid damage to the meter and user Non contact AC Electric Field Sensing To sense whether there is AC voltage or electromagnetic field please turn the range switch to...

Page 4: ...the measurement accuracy might be affected Battery specification AAA battery 1 5Vx2 Battery replacement Use a screwdriver to unscrew the screw on the battery cover top and remove the cover to replace...

Page 5: ...shock The measured signal is not allowed to exceed the specified limit to prevent electric shock and damage to the meter The range switch should be placed in the corresponding position during measurem...

Page 6: ...omkopplaren till l get f r AC sp nning S tt in den r da testkabeln i ut taget den svarta i COM uttaget och s tt sonderna i kontakt med b da ndarna av den uppm tta sp nningen paral lel anslutningen ti...

Page 7: ...l kretsen och laddar ur alla kondensatorer f r att undvika skador p m taren och anv ndaren Ber ringsfri v xelstr msf ltavk nning F r att k nna om det finns v xelsp n ning eller elektromagnetiskt f lt...

Page 8: ...d pip N r m tarens fr mre nde ligger n ra eluttaget eller n tsladd p cirka 200 V kommer m tarindikatorn att skilja det elektriska f ltets intensitet med gr nt gult och r tt fr n svagt till starkt och...

Page 9: ...ska placeras i motsvarande l ge under m tning ndra aldrig omr desinst llningen vid m tning detta f r att undvika skador p m taren Byt inte m tarens interna krets detta f r att undvika skador p m taren...

Reviews: