The UT123T is a pocket-size multimeter specially designed for home use. The compact 

structure makes it easy to hold in one hand, and the EBTN screen allows users to obtain 

clear readings at maximum angle. The multimeter is complied with EN61010-1:2010, 

EN61010-2-030:2010, and EN61326- 1:2013 safety standards and is able to safely operate 

within the CAT IlI 600V environment. Read safety information before use.

Features

• 

Automatic battery status detection.

• 

Automatic identification of ACV/DCV measurement

• 

Intelligent non-contact electric field detection, which distinguish-

es the weak electric field by a green light, the strong electric field by 

a yellow light, and the very strong electric field by a red light

• 

Full featured protection

Use

The meter has the function of battery self-checking, and can complete the battery status 

detection within 2 seconds at the moment of booting:

1. 

When the supply voltage is >2.7V, the indicator on the top of the meter lights 

up green for 2 seconds, indicating that the power is sufficient, and the 

meter enters the normal measurement mode accompanied by one beep.

2. 

When the supply voltage is within 2 .4V~2.7V, the indicator on the top of the 

meter lights up yellow, and the low battery symbol " " appears on the LCD.

3. 

When the supply voltage is <2.4V, the indicator on the top of the 

meter lights up red for 2 seconds, and then the meter powers 

off. It can only be used after replacing the batteries.

DC/ AC Voltage Measurement

• 

Turn the range switch to the AC voltage position;

• 

Insert the red test lead into the "

 " jack, 

black into the COM" jack, and make the probes 

in contact with both ends of the measured 

voltage (parallel connection to the load);

• 

Read the test results on the display.

The meter has the function of ACV/DCV automatic identification (voltage Z0.5V). If you 

want to measure voltage less than 0.5V, press the SELECT button to toggle the AC and 

DC voltage to lock the measurement mode; After pressing the SELECT button, the meter 

no longer has the function of ACV /DCV automatic identification, unless you turn the 

range switch or restart the meter!
Note:

• 

Do not measure voltage above 600Vrms. Although it is possible to measure higher 

voltage, it may damage the meter and hurt the user! If the LCD displays OL", it 

indicates that the voltage is over range. The input impedance of the meter is 10MQ. 

This load effect may cause measurement error when measuring high impedance 

circuits. If the measured impedance is < 10k , the error can be ignored (<0.1%).

• 

Be cautious to avoid electric shock when measuring high voltage.

• 

Test known voltage before use to confirm if the meter functions properly!

Resistance Measurement

1. 

Turn the range switch to the resistance measurement position;

2. 

Insert the red test lead into the "

 " jack, black into the 

COM" jack, and make the probes in contact with both ends of the 

measured resistance (parallel connection to the resistance);

3. 

Read the test results on the display.

Note:

• 

Before measuring the online resistance, switch off the power supply of the circuit, 

and fully discharge all capacitors to avoid damage to the meter and user.

• 

lf the resistance is not less than 0.52 when the test leads are short-

ed, please check if the test leads are loose or abnormal.

Summary of Contents for UT123T

Page 1: ...manual EN SV NO XXXXXXXXX Art no 40727 2020 08 24 Box 50435 Malm Sweden Uni T...

Page 2: ...e AC voltage position Insert the red test lead into the jack black into the COM jack and make the probes in contact with both ends of the measured voltage parallel connection to the load Read the test...

Page 3: ...ully discharge all capacitors to avoid damage to the meter and user Non contact AC Electric Field Sensing To sense whether there is AC voltage or electromagnetic field please turn the range switch to...

Page 4: ...the measurement accuracy might be affected Battery specification AAA battery 1 5Vx2 Battery replacement Use a screwdriver to unscrew the screw on the battery cover top and remove the cover to replace...

Page 5: ...shock The measured signal is not allowed to exceed the specified limit to prevent electric shock and damage to the meter The range switch should be placed in the corresponding position during measurem...

Page 6: ...omkopplaren till l get f r AC sp nning S tt in den r da testkabeln i ut taget den svarta i COM uttaget och s tt sonderna i kontakt med b da ndarna av den uppm tta sp nningen paral lel anslutningen ti...

Page 7: ...l kretsen och laddar ur alla kondensatorer f r att undvika skador p m taren och anv ndaren Ber ringsfri v xelstr msf ltavk nning F r att k nna om det finns v xelsp n ning eller elektromagnetiskt f lt...

Page 8: ...d pip N r m tarens fr mre nde ligger n ra eluttaget eller n tsladd p cirka 200 V kommer m tarindikatorn att skilja det elektriska f ltets intensitet med gr nt gult och r tt fr n svagt till starkt och...

Page 9: ...ska placeras i motsvarande l ge under m tning ndra aldrig omr desinst llningen vid m tning detta f r att undvika skador p m taren Byt inte m tarens interna krets detta f r att undvika skador p m taren...

Reviews: