III. Accessories

Open the package to check the accessories shown below. Please contact 
you supplier if any of them is founded missing or damage.
Standard accessories:
User manual ----------------------------------------------------  1 pc
Test lead 

1 pair

 --------------------------------------------------------  

1.5V AAA battery 

3 pcs

 ----------------------------------------------  

Magnetic hanger 

1 set

 ----------------------------------------------  

UT-CS06A AC current probe (optional)

1 pc 

 -------------------  

IV. Safety Information

Please pay attention to “Warning labels and sentences”. The warnings 
identify the operation may pose danger to user and cause damage to the 
multimeter or measured equipment.
The meter is in compliance with IEC/EN61010-1, 61010-2-033, Electromagnetic 
Radiation EN61326-1 Safety Standard, Double Insulation Standard, Overvoltage 
CAT III 600V, and Pollution Class 2. Failure to follow the operating instructions 
may compromise or lose the protection provided by the multimeter.
   Before use, please check the multimeter and test leads so as to prevent 

any damage or abnormal case. Please stop use if any abnormal case 
occurs, for example, test leads are exposed, casing is damaged, black 
screen or abnormal display occurs, or others. It is forbidden to use without 
cover closed in place, otherwise it may present a risk of electric shock.

   In case of damaged test leads, please replace by test leads same with 

model or electrical specification.

   Do not make contact with exposed wire, connector, unused input terminal 

or circuit during use.

   Use cautious when working with voltage over DC/AC 30V, please grip the 

test lead behind the finger guard to avoid electric shock.

   Set the multimeter at maximum range if the measured range is unknown.
   Do not apply overrated voltage or current between terminals, or between 

any terminal and grounding.

   Set the rotary switch to correct range. Disconnect test lead with measured 

circuit before switching the functional switch. It is forbidden to switch over 
during measurement, so as to avoid damage to the multimeter.

   Before measuring on-line resistance, diode or continuity, please switch off 

all powers of measured devices, and discharge all capacitors completely.

   Before measuring current, please check if the fuse of the multimeter is good, 

and switch off the measured current before connecting the multimeter 
with circuit, to avoid a risk of electric spark.

   Do not keep or use the multimeter in environments with high temperature, 

high humidity, inflammable and explosive substance, and strong 
electromagnetic fields.

   Do not alter the internal wiring without authorization to avoid damage to 

the multimeter.

   When the symbol “       ” shows on the LCD, please replace the battery 

in time to ensure measurement accuracy.

   Turn off the power in time after measurement. Remove the battery if the 

multimeter is not used for a long time.

    Optional magnetic hanging strap to enable performing measurement 
    without holding the multimeter by hand.
    The current of conductor can be measured without changing or disconnecting 
    the circuit, by connecting current probe externally.
    Drop proof: 2m
    CAT III 600V
    The user manual includes related safety information and warning prompt. 
    Please read the instructions carefully and strictly follow all warning and 
    precautions.

V. Electrical Symbols

Description

Description

Do not place equipment and 
its accessories in the trash. 
Please dispose properly 
according to the local regulation.

AC (Alternating Current)

DC (Direct Current)

Fuse

Double insulated

Grounding

Warning

Low battery

UKCA certification mark

Bluetooth communication

Conform to European Union standards

Conform to UL STD 61010-1, 61010-2-032
Certified to CSA STD C22.2 NO. 61010-1, 61010-2-032

Applicable to test and measure the circuit connected with the 
power distribution part of building’s low-voltage MAINS installation.

Applicable to test and measure the circuit connected with the 
power supply of building’s low-voltage MAINS installation.

Symbol

Symbol

VI. General Characteristics

● Maximum voltage between signal input terminal and COM terminal: See 
   voltage input protection instruction for each range
● Designed with 10A input terminal: Fuse 11A/1000V (energy: 30KA) 
   Φ10.3×38mm
● Display count: 60000
● Display uprate rate: About 5 times per second

UT117C User Manual

UT117C User Manual

Summary of Contents for UT117C

Page 1: ...UT117C P N 110401111679X High Precision True RMS Digital Multimeter User Manual...

Page 2: ...end guarantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damages caused by accident negligence misuse...

Page 3: ...d auto power off and Bluetooth II Features True RMS to ensure accurate measurement of non linearity load The ability to measure 20A 10 seconds of transient measurement LoZ function Low impedance to pr...

Page 4: ...asured devices and discharge all capacitors completely Before measuring current please check if the fuse of the multimeter is good and switch off the measured current before connecting the multimeter...

Page 5: ...IEC 61010 1 CAT 600V VII External Structure 1 NCV sensing end 2 LCD display 3 Functional buttons Used to select measurement functions 4 Rotary switch 5 A terminal 6 COM terminal 7 V terminal 8 Holder...

Page 6: ...our times at a frequency of 2Hz and the auto off function is disabled To restore auto range and auto off function please exit MAX MIN mode If the auto off function is disabled manually the multimeter...

Page 7: ...ction Composite sinusoidal signal generated by inverter or variable frequency motor can be measured through the LPF function as shown in Figure 6 below Long press SELECT again to exit LPF function 5 W...

Page 8: ...ent Do not input voltage over 30V DC AC to avoid personal injury Disconnect the test lead with measured circuit after all measurement operations are completed 5 Resistance measurement Figure 6 1 Set t...

Page 9: ...asurement under ACA mode of current probe the input current amplitude shall be greater than 10 of full range The frequency response is 45Hz 400Hz For range at 600 0A 1mV 1A AC DC The current probe mea...

Page 10: ...V AC please observe if the conductor of measured electric field is insulated so as to avoid personal injury Even the displayed result is that voltage is not present it does not mean voltage is present...

Page 11: ...ution Accuracy a of reading b digit Overload protection Input impedance About 10M Range to ensure accuracy 1 100 of range Least significant digit under short circuit 2 digits 600 00mV 0 01mV 1 30 600V...

Page 12: ...racy 1 100 of range The least significant digit at current range under open circuit is allowed to be 2 Note 10 20 A Perform measurement continuously for 10 seconds at most then stop for 15 minutes at...

Page 13: ...allowed to be about 5 under short circuit 12 Current probe measurement ACA DCA 600 0A 0 1A 1 8 3 600V AC DC 600 0A 0 1A 0 8 2 ACA DCA Range Resolution Accuracy a of reading b digit Overload protectio...

Page 14: ...a synchronizing and more Please refer to the use manual of iDMM2 0 for use of these functions 4 Uninstallation of the software Uninstall the software through the uninstallation function of mobile phon...

Page 15: ...o not keep in environments with high humidity high temperature and strong electromagnetic fields 2 Replace battery or fuse Figure 11 Warning 1 When the symbol shows on the LCD please replace the batte...

Reviews: