background image

 

 

Preface 

At first, thank you very much for using our product UT-P35&UT-P36 
high voltage isolating probes. This instruction manual includes safety 
summary, brief introduction, main specifications and operating basics etc. 
Please read the manual carefully prior to use the product. 

 

Warranty 
Instrance warrants that this product will be free from defects in materials 
and workmanship for a period of one (1) year from the date of shipment. 
If any such product proves defective during this warranty period, 
Instrance, at its option, either will repair the defective product without 
charge for parts and labor, or will provide a replacement in exchange for 
the defective product. Parts, modules and replacement products used by 
Instrance for warranty work may be new or reconditioned to like new 
performance. All replaced parts, modules and products become the 
property of Instrance. 
This warranty shall not apply to any defect, failure or damage caused by 
improper use or improper or inadequate maintenance and care. 

 

THIS WARRANTY IS GIVEN BY INSTRANCE WITH RESPECT TO 
THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, 
EXPRESS OR IMPLIED. INSTRANCE AND ITS VENDORS 
DISCLAIM ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE. INSTRANCE AND ITS VENDORS WILL NOT BE 
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR 
CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER 
INSTRANCE OR THE VENDOR HAS ADVANCE NOTICE OF THE 
POSSIBILITY OF SUCH DAMAGES. 

Summary of Contents for UT-P35

Page 1: ...UT P35 UT P36 High Voltage Isolating Probes Instruction Manual...

Page 2: ...1 Please read the instruction manual carefully to avoid injury and prevent damage to this product Ver 1 0 2021 05 19...

Page 3: ...lacement in exchange for the defective product Parts modules and replacement products used by Instrance for warranty work may be new or reconditioned to like new performance All replaced parts modules...

Page 4: ...able of contents 1 Safety Summary 4 2 Brief Introduction 5 3 Main Specification 6 4 Unpacking and Preparation for Use 8 5 General View of Product 9 6 General View of Accessories 10 7 Operating Basics...

Page 5: ...sconnect probes while they are connected to a voltage source Ground the product This product is indirectly grounded through the grounding conductor of the mainframe power cord To avoid electric shock...

Page 6: ...C peak AC accordingly UT P35 UT P36 high voltage isolating probe has over range alarm function It indicates with a red LED UT P35 UT P36 high voltage isolating probe is small and robust It has very hi...

Page 7: ...uts 8M Input capacitance Between each input to ground 7pF Between inputs 3 5pF Maximum measurable differential voltage 1 50 130V DC peak AC 1 500 1300V DC peak AC Maximum input voltage to earth 1000Vr...

Page 8: ...P35 60cm UT P36 30cm Output cable length 90cm Alligator clips 85 40 13 mm Pincer clips 160 45 13 mm Probe body 120 55 24 mm Weight probe only 160g Environment Specification Operating temperature 0 40...

Page 9: ...Instruction manual 1pcs AC adapter 1pcs Red alligator clip 1pcs Black alligator clip 1pcs Red pincer clip 1pcs Black pincer clip 1pcs 4 2 Preparation for use Please check the line voltage prior to con...

Page 10: ...9 5 General View of Product...

Page 11: ...View of Accessories UT P35 UT P36 high voltage isolating probe includes following accessories An AC adapter a couple of alligator clips and a couple of pincer clips 1 AC adapter 2 Alligator clips 3 P...

Page 12: ...probe power input connector The green POWER indicator lights e Select adapt attenuation range according to measured voltage When the measured voltage is over range the red OVER RANGE indicator lights...

Page 13: ...ld be lower than 10MHz Otherwise the errors will be larger c The probe and measuring instrument should warm up for 20 minutes if want to get high accuracy measuring result 7 3 Troubleshooting The Powe...

Page 14: ...13...