10
1.6 User Interface
1
2
3
4
5
6
7
8
9
Picture 1-5Oscilloscope display interface
①.
Trigger
Status
Identification
:
Includes
TRIGED
(
has
been
triggered
),
AUTO
,
READY
,
STOP
,
and
ROLL
(
rolling
).
②.
Time
Base
Scale
:
Indicates
the
amount
of
time
represented
by
one
grid
on
the
horizontal
axis
,
which
can
be
adjusted
by
the
horizontal
SCALE
knob
.
③.
Sampling
Rate
/
Memory
Depth
:
Indicates
the
current
sampling
rate
and
storage
depth
.
④.
Horizontal
Displacement
:
Shows
the
horizontal
displacement
value
of
the
waveform
,
which
can
be
adjusted
by
turning
the
horizontal
POSITION
knob
.
Press
the
knob
to
return
the
displacement
value
back
to
0
.
⑤.
Trigger
Status
:
Displays
trigger
source
,
type
,
slope
,
coupling
,
level
,
etc
.
a
.
Trigger
source
:
There
are
seven
states
:
CH1
~
CH4
,
AC
Line
,
EXT
,
and
EXT
/
5
.
CH1
~
CH4
will
each
be
of
a
different
trigger
color
,
for
example
,
is
CH1
.
b
.
Trigger
type
:
The
types
are
edge
,
pulse
width
,
video
,
slope
,
and
advanced
trigger
.
For
example
,
is
an
edge
trigger
.
c
.
Trigger
edge
:
The
types
are
rising
,
falling
,
and
any
kinds
.
For
example
,
Indicates
trigger
at
the
rising
edge
.
d
.
Trigger
coupling
:
The
types
are
DC
,
AC
,
high
frequency
suppression
,
low
frequency
suppression
,
and
noise
suppression
.
For
example
,
indicates
DC
coupling
.
e
.
Trigger
level
:
Indicates
the
current
trigger
level
value
,
corresponding
to
the
on
the
right
side
of
the
screen
.
Adjust
the
LEVEL
knob
in
the
trigger
control
area
to
change
this
parameter
.
⑥.
CH1
Vertical
Status
:
Displays
CH1
activation
state
,
channel
coupling
,
bandwidth limitation
,
vertical
scale
,
and
probe
attenuation
coefficient
.
Channel
activation
state
:
When
the
background
includes
the channel
color
,
the
channel
is
activated
.
Press
the
button
1
,
2
,
3
,
4
to
activate
or
open
/
close
the
corresponding
channel
.
Channel
coupling
:
Includes
DC
,
AC
,
and
grounding
.
For
example
,
is
DC
coupling
in
CH1
.
Bandwidth
limitation
:
Enable
and
there
will
be
a
icon
shown
on
CH1
vertical
status
bar
.
Vertical
scale
:
When
CH1
is
activated
,
the
vertical
scale
parameter
can
be
adjusted
by
the
SCALE
knob
in
the
vertical
control
area
.
Probe
attenuation
coefficient
:
Displays
CH1
probe
attenuation
coefficient
:
0
.
001X
,
0
.
01X
,
0
.
1X
,
1X
,
10X
,
100X
,
1000X
.
⑦.
USB
Device
Indicator
:
Displays
the
indicator
when
the
USB
device
interface
is
connected
to
a
USB
storage
device
such
as
a
USB
flash
disk
.
⑧.
Current
date
and
time
.
⑨.
Operation
Menu
:
Displays
the
current
operation
menu
.
Press
F1
~
F5
can
change
the
corresponding
submenu
content
.
⑩.
Analog
Channels
and
Waveforms
:
Displays
CH1
~
CH4
channels
and
waveforms
,
the
color
of
the
channel
indicator
is
consistent
with
the
waveform
.