3
Owner’s manual
EN
OVERVIEW
Warning
To avoid possible electric shock or personal injury, and to avoid
possible damage to the Meter or to the equipment under test,
adhere to the following rules:
● Before using the Meter inspect the case. Do not use the Meter if
it is damaged or the case (or part of the case) is removed. Look for
cracks or missing plastic. Pay attention to the insulation around the
connectors.
● Inspect the test leads for damaged insulation or exposed metal.
Check the test leads for continuity. Replace damaged test leads
with identical model number or electrical specifications before us
-
ing the Meter.
MIE0141/MIE0142 multimeter is a hand-held 3 1/2 digital display
digital multimeters with advanced design, multiple entire functions,
novel figurations and reliable performance. This meter is fully ca
-
pable to measure voltage both AC and DC, DC current, resistance,
inductance, temperature and forward voltage drop of diode, tran-
sistor, hFE and continuity test etc. Please use multi-purpose socket
to measure SMT as well. This operating manual covers information
on safety and cautions to fulfill CE mark standard. Please read the
relevant information carefully and observe all the warnings and
notes strictly.
Warning:
To avoid electric shock or personal injury, read the
“Safety information” and „Rules for Safe Operation” carefully before
using the meter.
RULES FOR SAFE OPERATION