background image

Err5

 

Err4

Err3

Err2

Err1

Err

 

112x50x25mm

50m

70m

100m

120m

-

20˚C~60˚C

0˚C~40˚C

20%~80%RH

1.5V 2xAAA

1

2

3

4

5

±(2mm+5*10   D

)

-5

LM50A

LM70A

LM100A

LM120A

Class II

(
     height

  

     Press 

FUNC

 3x. 

     Press      to measure the length of the hypotenuse (a).
     Press      to measure the length of the base-side (b).
     The meter will automatically calculate the length of the leg (x).

1) Measure the hypotenuse and base-side, indirectly measure the 

(2) Measure the leg and base-side, indirectly measure the hypotenuse  

      Press 

FUNC

 4x. 

      Press      to measure the length of the leg (a).
      Press      to measure the length of the base-side (b).
      The meter will automatically calculate the length of the hypotenuse (x).

(3) Press FUNC 5x, the hypotenuse flashes 

      Press     to measure the length of the hypotenuse (a).
      Press     to measure the length of another hypotenuse (b).
      Press     to measure the length of the base-side ©.
      The meter will automatically calculate the length of the leg (x).

(4) Press FUNC 6x, the hypotenuse flashes 

      Press      to measure the length of the hypotenuse (a).
      Press      to measure the length of the base-side (b).
      Press      to measure the length of another hypotenuse ©.
      The meter will automatically calculate the length of the leg (x).

      In the Pythagorean measurement mode, the length of the leg must be 
      less than the length of the hypotenuse; otherwise the meter will display 
      an error signal prompt. In order to ensure the measurement accuracy, 
      users should make sure to measure from the same starting point and in 
      the order of hypotenuse and leg.

6. Addition/Subtraction

The single distance measurement values can be added or subtracted. After 
getting the result when taking a single distance measurement, press         to 
enter the addition/subtraction mode. 

Short press +, the "+" symbol will show on the primary display, and then it 
will enter the addition mode. The addition value of the last and the current 
measurement values will show on the display.

Short press    , the "

﹣" 

symbol will show on the primary display, and then  

it will enter the subtraction mode. The subtraction value of the last and the 
current measurement values will show on the display.

Not only the distance can be added and subtracted, but also the area and 
the volume.
Area addition: Measure the first area and get the result, as shown in Figure 1 
below. Then press      to measure the second area and get the result, as 
shown in Figure 2 below, and a plus sign will be displayed in the lower left 
corner. Finally, press      to get the result of adding these two areas, as shown 
in Figure 3. The addition and subtraction of volume is similar to it.

7. Data Storage

If the current data is valid when measuring, press and hold      for 3 seconds, 
and the data will be automatically stored in the meter memory. In the area, 
volume and indirect measurement modes, the data can also be stored after 
all the tests are over. At this time, the meter will store the complete 
measurement record under this mode.

8. View/Delete Data

Short press      to query the stored data. Press + to scroll forwards, and press
    to scroll backwards. When viewing data, short press         to delete the 
current record, and long press        to delete all records. Press      or     to exit.

Error Codes

Resolution

Use the meter in 
designated environments.

Measure the target point with 
strong reflection ability.

Measure the target point 
with weak reflection ability.

Replace batteries.

Use the meter within the range.

Re-measure to ensure that the 
hypotenuse is longer than the leg.

Cause

Out of distance 
measurement range

Signal too weak

Signal too strong

Battery power too low

Out of operating 
temperature range

Pythagorean 
measurement error

Code

Specifications

Items

Measurement range

Measurement accuracy

Continuous measurement

Area/volume measurement

Pythagorean measurement

Addition/subtraction

Area/volume 
addition/subtraction

Max/min

Self-calibration

Laser class

Laser type

Data storage

Auto laser off

Auto power off

Battery life

Sound prompt

Storage temperature

Operating temperature

Storage humidity

Batteries

Product size

Class 2 630-670nm, 

1mW

99 groups

20s (single measurement)

About 150s

Up to 8000 measurements

d" means actual distance.

"

** Under harsh environments, such as excessive sunlight and ambient 
    temperature fluctuations, weak reflection on reflective surfaces, and 
    insufficient battery power, the measurement results will have errors. At this 
    time, using the target reflector can improve the measurement accuracy.

Maintenance

Do not place the meter in a high temperature and humidity environment for 
a long time. When not using the meter for a long time, please take out the 
battery and put the meter in the carrying bag, and store it in a cool and dry 
place.

Remove dirt with a moist, soft cloth. Do not use aggressive detergents or 
solutions. The laser window and focusing lens can be wiped according to the 
method of wiping the optical device.

Packing List

All accessories are shown in the table below.

Accessories

Meter

Carrying bag

AAA batteries

User manual

Gift box

Quantity

1

1

2

1

1

Items

Figure 1

Figure 2

Figure 3

Reviews: