9
MANUAL - SPRAY GUN CLEANERS - UG5000W SERIES
Revision 2019-3
CLEANING WITH THE WASH GUN
• To clean with the Wash Gun, make sure
the Brush Control lever on the front of the
unit is in the "Close" position (horizontal).
Place the Spray Containment Chamber on
the Work Screen in the wash tank. Place the
nozzle of the Wash Gun into the paint chan-
nel (where he cup joins the spray gun) as
shown in photo. Place the cap of the spray
gun in the Containment Chamber.
• Step on the foot pedal and squeeze the trig-
ger of the spray gun while squeezing the
trigger of the Wash Gun to send a pressur-
ized flow of water through the paint channel.
Use the Wash Gun Flow Control on the side
of the cabinet to adjust the flow as necessary.
The Spray Containment Chamber contains
the spray. Allow water to flow for about 20
seconds to clean the paint channel.
TO ADJUST THE FLOW CONTROL
• Use the Flow Control to adjust the flow of water
on the Water Gun and the Brush.
To increase the flow loosen the locking nut
and rotate the dial anti-clock wise and then ighten the
locking nut.
CLEANING WITH THE BRUSH
• If necessary, use the Flow-through Brush to clean the outside of the spray gun. Make sure the Brush Control
Lever on the front of the unit is in the "Open" position (vertical). Step on the foot pedal to send a pressurized
flow of water through the Brush. To control the flow of water through the Brush, use the Brush Flow Control
on the side of the cabinet as necessary.
• Use the blow gun to dry the inside and outside of the spray gun.
• To maximize the dying operation, dry the paint channel with the Blow Gun while squeezing the trigger of the
spray gun. As a final check for dryness, remove the cap and check it for moisture.
NOTE: THOROUGH DRYING OF THE GUN BOTH INSIDE AND OUT WILL PREVENT
CORROSION.
Flow Control Flow Control
Water Gun
Brush
Wash
Gun
Spray
Gun
Spray
Containment
Chamber