MANUAL - SPRAY GUN CLEANERS - UG5000 SERIES
Revision 2013-02
6
•
Move the pail outside the unit. Remove the two filters. Pour a full bottle of Uni-ram Aqua Kleen into
the pail and add tap water until the combined liquid level reaches the bottom of the filter holder.
Replace filter.
•
Insert the manual wash suction tube into the pail between the Filter Holder and the wall of the pail.
Move the pail into the cabinet.
OPERATION
LEFT TANK (UG4000, SOLVENT)
PRE - CLEAN
• Disconnect the spray gun from the air hose. Pour paint from the cup (when present) into a 5 gallon
pail (not supplied).
•
Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling.
SELECTION OF NOZZLE EXTENSION
780-3530
INSTALLED. HOLES PROVIDE SOLVENT TO CEAN DISPOSABLE CUP ADAPTOR.
CANNOT BE USED FOR CONVENTIONAL SYSTEMS.
110-430PPS
HOLES PROVIDE SOLVENT TO CLEAN DISPOSABLE CUP ADAPTOR. MAY ALSO BE
USED FOR CONVENTIONAL SYSTEMS WITH LARGER OPENINGS IN NECK OF CUP.
110-430
FOR CONVENTIONAL SYSTEMS ONLY WITH SMALLER OPENINGS IN NECK OF CUP.
CLEANING SPRAY GUNS AND CUPS
•
Loosen the air cap of the spray gun two full turns.
•
Lock the trigger in the open position with the Trigger Lock Spring.
•
To prevent liquid from entering the air passgae during automatic
cleaning, insert the white plastic Air Passage Plug into the Spray
Gun's air inlet. If the air inlet has a male threaded connector instead
of a quick connect use the knurled nut attached to the Trigger Clamp
(included).
•
Place spray guns facing corner jets. Placement depends on
type of spray gun
. See pictures
below. Place cups onto the low spray jets and cup holders.
•
Close the lid and turn the “TimerControl” knob (left side) clockwise to start cleaning. The cleaning
cycle takes about 60 seconds
•
Push and hold the "Rinse Cycle Control" button for about 5 seconds to rinse guns with clean sol-
vent. This will send a pre-set amount of clean solvent (100 cc) through the jets. Wait 30 seconds
for the Rinse Pump to fully recharge before repeating.
•
Push and hold the "Air Rinse Control" button for about 3 second to air-rinse the guns.
•
The Air Blow Gun can also be used to ait dry the Spary Gun.
The
s
olvent flow per clean-rinse cycle is limited to 100 cc to minimize consumption. This quantity
is usually sufficient to clean the inside pasages of the spray guns.
USING THE FLOW-THROUGH BRUSH
•
To deliver clean solvent through the Brush for rinsing, step on the foot pedal.
•
Solvent flow is set at the factory but may be adjusted using the left side "Brush Flow Control".