CLEANING SPRAY GUNS AND CUPS

Loosen the air cap of the spray gun two full turns.

Lock the trigger in the open position with the Trigger Lock Spring.

Plug air inlet of spray gun with cap to prevent solvent from entering passage. Caps are supplied
in the accessory kit.

Place spray guns facing corner jets. Placement depends on 

type of spray gun

. See pictures

below. Place cups onto the low spray jets and cup holders.

CLEANING SPRAY GUNS AND CUPS - continued

Close the lid and turn the “Auto Wash Timer” knob clockwise to start cleaning. The cleaning
cycle takes about 60 seconds 

Push and hold the "Air Rinse" button for about 3 second to air-rinse the guns.

Push and hold the "Clean Rinse" button for about 5 seconds to rinse guns with clean      sol-
vent. This will send a pre-set amount of clean solvent (100 cc) through the jets. Wait 30 sec-
onds for the Rinse Pump to fully recharge before repeating.
The s

olvent flow per clean-rinse cycle is limited to 100 cc to minimize consumption. This quanti-

ty is usually sufficient to clean the inside pasages of the spray guns.

USING THE MANUAL WASH and MANUAL RINSE FEATURES

For models with manual wash brush, open the lid and step on the foot pedal (left side). A dedi-
cated pump delivers wash solvent through the brush. 

For models with the Manual Rinse feature, open the lid and step on the foot pedal (right pedal
on two-pedal models). Clean solvent is delivered through the brush.
S

olvent flow through the rinse brush is limited to minimize clean solvent consumption. 

HOSE CLEANING ONLY UG5500E

Models with this feature to clean a paint feeder hose up to 100 feet (30m) long. Connect the to
the two fittings, one on the front and one on the right side. Rotate the “Mode Selector” to the
right (Horizontal position) and turn the Timer knob clockwise to start the automatic cleaning
cycle. 

To air rinse the hose, push and hold the “Air Rinse” button

To rinse the hose with the clean solven, push and hold the “Clean Rinse” button for about 5

seconds. This will use about 100 cc of clean solvent. Wait 30 seconds for the Rinse Pump to

fully recharge before repeating.

Disconnect the hose.

AFTER CLEANING

Remove the guns and cups from the tank and wipe them dry. Do not store spray guns in the
tank.

Summary of Contents for UG5000E

Page 1: ...LVENT SPRAY GUN CLEANERS UG5000E UG5000DVM AND UG5500E USA 4 788 836 CANADA USA 5 213 117 ENGLAND EUROPE 0300248 ITALY SWEDEN 0300248 GERMANY FRANCE 8110528 0 JAPAN UNI RAM CORPORATION ONTARIO CANADA...

Page 2: ...T PAIL SETUP 6 GROUND WIRE INSTALLATION 7 OPERATION PRE CLEAN 7 CLEANING SPRAY GUNS AND CUPS 8 USING THE MANUAL WASH and MANUAL RINSE FEATURES 8 HOSE CLEANING ONLY UG5500E 8 AFTER CLEANING 8 DAILY MAI...

Page 3: ...AUTIONS AND WARNINGS Always disconnect this machine from power sources before performing maintenance Do not smoke or use near open flames sparks or heat Ground pails and cabinet using supplied groundi...

Page 4: ...T NOT SHOWN GROUND WIRE INSIDE ONE FOR RIENS PUMP AND ONE FOR EACH SUCTION PIPE VENT TANK UG3000DA AUTO WASH TIMER AIR RINSE CLEAN RINSE ADJUSTABLE FOOT FOOT PEDAL FOR MANUAL RINSE UG4000 DVM NOT SHOW...

Page 5: ...ing contact your supplier LOCATION Position in a well ventilated area away from sparks heat and open flames LEVELING VENT AND AIR SUPPLY Level the machine using the adjustable legs Attach a vent hose...

Page 6: ...e Suction Pipe and the Rinse Pump Cut the strap holding them together Do not cut the other straps holding the black and blue tubes The Suction Pipe is shown in the section Replacement Parts Inside rig...

Page 7: ...the cabinet to an external grounded object 2nd ground wire is connected to suction pipe left UG4000DVM 3rd connected to rinse pump and 4th one connected to suction pipe right UG3000DA OPERATION UG400...

Page 8: ...his quanti ty is usually sufficient to clean the inside pasages of the spray guns USING THE MANUAL WASH and MANUAL RINSE FEATURES For models with manual wash brush open the lid and step on the foot pe...

Page 9: ...t the Suction Pipe from the Drain Valve and remove the pipe from the pail Move the pail out of the cabinet and recycle or dispose of the wash solvent Remove the Rinse Pump from the other pail move the...

Page 10: ...Follow Procedure 4 Blocked Passage in Solvent Line WASH SOLVENT OR WATER DOES NOT FLOW AND PUMP MAKES A HISSING SOUND Water in air line causes pump to stall Follow Procedure 2 Blockage in Air Passage...

Page 11: ...int used and for Automatic Spray Gun Cleaners Increase air pressure to a minimum of 85 PSI Remove and clean by blowing air through the jets If not successful replace GUNS NOT CLEAN WASH SOLVENT IS MIL...

Page 12: ...due to a blocked air passage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the diaphragm pump...

Page 13: ...13 FLOW DIAGRAM Shows the flow of solvent and compressed air MANUAL SPRAY GUN CLEANERS UG5000 SERIES Revision 2007 11...

Page 14: ...10 171 TANK DRAIN VALVE 110 356 TAPER NOZZLE 100 350 SPRAY JETS 140 361F DELIVERY TUBE ASSY WITHOUT JETS 120 318 HANDLE 144 390 FLOW THROUGH BRUSH ASSY INSIDE DETAIL OF GUN CLEANER TANK SOLVENT DETAIL...

Page 15: ...n 110 430 Nozzle Adapter All models Push On 110 430MJ Nozzle Adapter SATA Mini Jet Threaded 110 430MJP Nozzle Adapter SATA Mini Jet Push On 110 430L1 Nozzle Adapter Threaded SATA 0 6 1 0 litre cups 11...

Page 16: ...or the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the produ...

Reviews: