MANUAL - SPRAY GUN CLEANERS - UG1000-3000 SERIES
6
SOLVENT SELECTION
The adhesion quality of automotive paint has dramatically improved in recent years. The choice of sol-
vent is critical. Only use good quality solvent that is formulated for your paint and intended for use
with automatic spray guns cleaners.
SOLVENT PAIL SETUP
•
Open the door to the base cabinet
•
Move the Drain Valve handle to the "closed" (horizontal) position if it is not already there. See
picture on right.
•
One 5-Gal (19 L) pail of solvent is required. Place the pail in front of the machine.
•
Disconnect the Suction Pipe from the Drain Valve by pushing the gray button and bring pipe
outside of the cabinet.
•
Move the pail into the cabinet and re-connect the Suction Pipe to the Drain Valve. Insert suction
pipe into the pail.
GROUND WIRE INSTALLATION
•
Three ground wires are provided to discharge static electricity. To work properly, all three must
be installed correctly. Connect the two wires inside the cabinet to the pails, one to each, and the
wire on the outside back of the cabinet to an external grounded object.
Drain Valve