TM 3254 

 

 

 

 Fig.3 

Threaded 

design: 10-EVSA 24Ü

 

 

 

 

 

Fig.4 

Threaded design: 10/40-EVS 5Ü 

 

 

Summary of Contents for EVSxxU Series

Page 1: ...ation for the use in explosion prone areas guideline 94 9 EC 3 0 Handling 3 1 Transport 3 2 Storage 3 3 Handling before mounting 4 0 Product Description 4 1 Function 4 2 Technical data 4 3 Marking 5 0...

Page 2: ...es are met The manufacturer reserves the right of any technical change and improvement The use of these operating instructions suppose the qualification of the user according to paragraph 2 3 qualifie...

Page 3: ...X PT 16 40 EVS NH O O O O O O PT 40 Test pressure to perform leakage test No FUNCTION TEST X Acceptance test certificate 3 2 O Acceptance test certificate 3 2 possible not available Voltage VDC 12 44...

Page 4: ...and regulations must be observed 2 3 Qualified staff These are persons who are familiar with erection assembly starting operation and maintenance of the product and who have special qualifications acc...

Page 5: ...alve flanges The goods to be transported must be carefully treated During transport the valve must be protected against strokes impacts or vibration The coat of lacquer may not be damaged Transport te...

Page 6: ...21 2 80 3 100 4 125 150 6 4 EVS 008 2 008 2 010 012 014 016 018 019A5 018A1 018A1 019A2 10 EVS 010 010 010 012A5 014A5 016A5 019A5 018A1 018A1 019A1 019A2 40 EVS 019A5 Drive types with A consist of p...

Page 7: ...ve must not be used as a fixed point it is supported by the pipework system Protect valves from soiling particularly during construction work Thermal expansion of the pipework must be equalized using...

Page 8: ...work was carried out and completed as described in this operating manual Depending on the field of application the operation safety order must be observed Check the data on material pressure temperatu...

Page 9: ...t becomes damaged only applies to flange version Fig 1 thread version Fig 2 1 2 the spare parts kit should be used Flanged version Fig 1 4 10 40 EVS Loosen hex bolts 900 1 and remove housing flange 10...

Page 10: ...nty will not be accepted The customer shall have no right to the supply of a replacement valve Maintenance work installation of parts from other manufacturers any modifications to the design and natur...

Page 11: ...assumed This also applies for spring loaded components in fluid filled rooms In case of electric drives sensors or other electric components the application as per 94 9 EC is to be checked separately...

Page 12: ...________________________________________________________________________________________________ 220100 098 04 Page 12 17 Release 08 2013 TM 3254 11 0 Sectional Drawing 11 1 Fig 1 Flange design 4 10 4...

Page 13: ..._______________________________________________________________________________________________________ 220100 098 04 Page 13 17 Release 08 2013 TM 3254 Fig 2 Threaded design 4 EVS 2 Spare part kit to...

Page 14: ...nslation EVS _______________________________________________________________________________________________________ 220100 098 04 Page 14 17 Release 08 2013 TM 3254 Fig 3 Threaded design 10 EVSA 24 F...

Page 15: ...e 503 1 1 3 Druckfeder Pressure spring 503 2 1 Druckfeder Pressure spring 800 1 Magnet Antrieb Solenoid drive 900 1 4 6 8 12 Sechskantschraube Hex head screw 901 1 Sechskantmutter Hex nut 902 1 1 Bolz...

Page 16: ...llation length A 2 108 118 127 140 165 203 216 241 292 406 4 EVS B 240 240 290 320 370 380 426 440 470 510 550 B 320 320 380 420 490 520 586 600 630 670 710 C 106 106 127 127 153 153 191 191 191 191 1...

Page 17: ...ounting manual translation EVS _______________________________________________________________________________________________________ 220100 098 04 Page 17 17 Release 08 2013 TM 3254 12 0 Declaration...