background image

www.ungerglobal.com

25

ENGLISH

RO-Reverse osmosis filter

Function overview

RO-Reverse osmosis filter

RO60C: Resin filter

9. The integrated TDS meter

9.1. Use

• 

Press the “POWER“ button to activate the unit.

• 

RO60C: To show the value of the incoming pure water in the resin filter, press “IN“. This 
value shows the quality of the water after filtering through the osmosis filter. The value of 
the filtered, outgoing water downstream the resin filter is shown with “OUT“.

• 

RO60S: The diode for the inlet value “IN” has been connected directly downstream the  
pre-filter and the diode for the outlet value “OUT” downstream the membranes.  
Thus, you are measuring the value of the incoming water and the water filtered by the 
system.

• 

The value takes a little time to adjust. The most precise value is indicated after approx. 10 
seconds.

• 

When the “x10“ indication appears, a value of over 999 ppm has been measured.  
Now multiply the value indicated by 10.  
If then, e.g., “143 x10“ is indicated in this mode, the correct value is 1430 ppm

.

• 

The TDS meter switches off automatically after approx. 30 seconds.

9.2. Care

• 

In principle, this TDS meter does not require any care. Nevertheless, the following points 
should be observed:

• 

Never touch the sensors, as the oil in the skin can affect the correct TDS values.

• 

Use alcohol to clean the sensors and allow them to dry in the air.

• 

If you find that the values indicated can no longer be correct, or if “BAT” is displayed, 
replace the batteries.

9.3. Replacing the batteries

• 

If the display becomes pale or shows faulty indications, the batteries should be replaced.

1.  Unscrew the four metal screws (not the plastic screws) on the bottom and remove the 

panel.

2.  Remove the batteries.
3.  Always replace both batteries (Type AA). Ensure that the polarity is correct.
4.  Close the panel again and screw it tight. It is not necessary to recalibrate the device.

10. Pump control system

The pump control system is in the black box on the right above the pump. 
The unit is reset and restarted with the red button. This is, e.g., necessary 
if there is too little pressure at the inlet. 

Summary of Contents for HiFlo Ro-Moobil RO60S

Page 1: ...NGSHANDLEIDING INSTRUCCIONES DE MANEJO ISTRUZIONI PER L USO ENGLISH DEUTSCH FRANCAIS NEDELANDS ITALIANO ESPAGNOL RO60S T Umkehr Osmose Filter Reverse osmosis filter Filtre osmose inverse Filtro a osmo...

Page 2: ...3 1 Scope of delivery 19 4 Shipping packing 20 4 1 Receiving inspection 20 4 2 Claims 20 5 Start up 20 6 Description of use of the osmosis system 22 6 1 Switching off the system 22 6 2 Maintenance ca...

Page 3: ...f contamination at the latest however every 6 months Recommendation Install an external residual current circuit breaker between the power supply in order to exclude risks as a result of surges These...

Page 4: ...m IP 65 1 6 Conversions and modifications to the device Due to safety reasons unauthorised modifications are not allowed Original parts and accessories are specifically designed for this reverse osmos...

Page 5: ...prevent damage to the system and modules please thoroughly read and observe the operating instructions prior to installation and start up ATTENTION The fed water must be in compliance with the German...

Page 6: ...the membrane while the saline solution is concentrated In the technical reverse osmosis process the concentrated solution is referred to as concentrate which is continuously drained from the system a...

Page 7: ...C water temperature l h approx 700l approx 750l Pump connection 1 1 kW Standard feed water connection 1 Standard concentrate connection G3 4 Standard permeate connection G3 4 Height 1230 mm Width 750...

Page 8: ...damage to the company in whose name the shipping company delivered the system to you Please save the packing material for return shipment only if delivered by a forwarding agent Claims based on shippi...

Page 9: ...ent 9 The cleaning water is now available ATTENTION Avoid banking up of the concentrate The hose to the concentrate outlet must move freely and must not be kinked as otherwise the membrane s will be d...

Page 10: ...ear by an authorised dealer or Unger 6 2 1 Pre filter Prior to each start up visually check the degree of contamination of the pre filter 3 and replace if necessary 6 3 Anti freeze protection The syst...

Page 11: ...th the transverse hole must be at the bot tom 3 Next fill the supplied membrane protection agent into the filter cup and firmly attach it again 4 Connect the system to the water supply only No power 5...

Page 12: ...minutes and only then connect the hoses to the right and left sides of the resin filter Please do not confuse the inlet and outlet Vent the resin filter by pressing the red button 8 3 Replacing the re...

Page 13: ...this mode the correct value is 1430 ppm The TDS meter switches off automatically after approx 30 seconds 9 2 Care In principle this TDS meter does not require any care Nevertheless the following point...

Page 14: ...T www ungerglobal com 74...

Page 15: ...75...

Page 16: ...U L osmose inverse type RO60C RO60S avec le num ro du constructeur cf plaque signal tique a t d velopp e con ue et fabriqu e conform ment aux directives CE mentionn es ci dessus La documentation techn...

Reviews: