background image

www.ungerglobal.com

17

ENGLISH

RO-Reverse osmosis filter

General information on reverse osmosis

2. General information on reverse osmosis

The reverse osmosis process is an eco-friendly, physical technology for desalination 
of drinking water without chemicals, for the purpose of generating pure water for 
industry and cleaning.

The advantages of the reverse osmosis process compared to other desalination meth-
ods are substantial:

• 

Maximum removal of all dissolved and dispersed water constituents (anions and cations 
of salts, airborne particles, colloids, organic compounds, etc.).

• 

Low operating costs, high use-value, quick amortisation.

• 

Minimal pre-treatment.

• 

Continuous operation.

• 

Small space requirement.

• 

High and consistent pure water quality.

• 

User-friendly and eco-friendly method, requiring no regeneration of the 

• 

membrane since no acids or bases are used as in chemical desalination.

Important information

To prevent damage to the system and modules, please thoroughly read and
observe the operating instructions prior to installation and start-up!

ATTENTION!

The fed water must be in compliance with the German Drinking Water Regulation. It 
must be completely free of iron-manganese heavy metals (max. 0.05 mg/l manganese, 
max. 0.2 ml/l iron); the maximum silicate (SiO2) content may not exceed 20 mg/l. In ad-
dition, the feed water must not contain any barium and strontium. RO60C and RO60S 
are already equipped with a carbon pre-filter as standard equipment.

It is essential to also observe the following:

• 

The system must be connected to a cold water supply.  
The water temperature shall be max. 25°C.

• 

If the raw water supply or power supply is interrupted for more than 1 week, the 
system must be prepared according to the storage regulations. Another possibility 
is to operate the system at least every 7 days for approx. 5 minutes. 

• 

Preparation for storage regulations, see also item 7.

• 

Please make sure filters are replaced on a regular basis (pre-filters, as well as any 
installed activated carbon filter).

RO-Reverse osmosis filter

Safety regulations

Summary of Contents for HiFlo Ro-Moobil RO60S

Page 1: ...NGSHANDLEIDING INSTRUCCIONES DE MANEJO ISTRUZIONI PER L USO ENGLISH DEUTSCH FRANCAIS NEDELANDS ITALIANO ESPAGNOL RO60S T Umkehr Osmose Filter Reverse osmosis filter Filtre osmose inverse Filtro a osmo...

Page 2: ...3 1 Scope of delivery 19 4 Shipping packing 20 4 1 Receiving inspection 20 4 2 Claims 20 5 Start up 20 6 Description of use of the osmosis system 22 6 1 Switching off the system 22 6 2 Maintenance ca...

Page 3: ...f contamination at the latest however every 6 months Recommendation Install an external residual current circuit breaker between the power supply in order to exclude risks as a result of surges These...

Page 4: ...m IP 65 1 6 Conversions and modifications to the device Due to safety reasons unauthorised modifications are not allowed Original parts and accessories are specifically designed for this reverse osmos...

Page 5: ...prevent damage to the system and modules please thoroughly read and observe the operating instructions prior to installation and start up ATTENTION The fed water must be in compliance with the German...

Page 6: ...the membrane while the saline solution is concentrated In the technical reverse osmosis process the concentrated solution is referred to as concentrate which is continuously drained from the system a...

Page 7: ...C water temperature l h approx 700l approx 750l Pump connection 1 1 kW Standard feed water connection 1 Standard concentrate connection G3 4 Standard permeate connection G3 4 Height 1230 mm Width 750...

Page 8: ...damage to the company in whose name the shipping company delivered the system to you Please save the packing material for return shipment only if delivered by a forwarding agent Claims based on shippi...

Page 9: ...ent 9 The cleaning water is now available ATTENTION Avoid banking up of the concentrate The hose to the concentrate outlet must move freely and must not be kinked as otherwise the membrane s will be d...

Page 10: ...ear by an authorised dealer or Unger 6 2 1 Pre filter Prior to each start up visually check the degree of contamination of the pre filter 3 and replace if necessary 6 3 Anti freeze protection The syst...

Page 11: ...th the transverse hole must be at the bot tom 3 Next fill the supplied membrane protection agent into the filter cup and firmly attach it again 4 Connect the system to the water supply only No power 5...

Page 12: ...minutes and only then connect the hoses to the right and left sides of the resin filter Please do not confuse the inlet and outlet Vent the resin filter by pressing the red button 8 3 Replacing the re...

Page 13: ...this mode the correct value is 1430 ppm The TDS meter switches off automatically after approx 30 seconds 9 2 Care In principle this TDS meter does not require any care Nevertheless the following point...

Page 14: ...T www ungerglobal com 74...

Page 15: ...75...

Page 16: ...U L osmose inverse type RO60C RO60S avec le num ro du constructeur cf plaque signal tique a t d velopp e con ue et fabriqu e conform ment aux directives CE mentionn es ci dessus La documentation techn...

Reviews: