background image

Mirage   M-­‐125   /   M-­‐115   Operating   &   Maintenance   Instructions   

   

5   

6.

 

Confirm   electrical   sprinkler   actuation   and   operation   once   all   connections   to   the   
control   system   have   been   completed.      

   

6.0   Winterizing

   

Prior   to   the   beginning   of   frost   or   the   onset   of   winter,   the   sprinkler   should   be   drained   of   as   
much   residual   water   as   possible.   

1.

 

Using   an   air   compressor,   displace   as   much   residual   water   in   the   mainline   and   sub-­‐
lateral   piping   systems   as   possible.      Open   the   sprinkler   head   manually   and   allow   
water   and   air   to   bleed   from   the   system.      Stop   applying   compressed   air,   only   after   air   
and   no   water   is   observed   exiting   the   sprinkler   nozzle.   

2.

 

Some   systems   maybe   designed   with   automatic   drain   valves   that   may   be   winterized   
by   gravity.         

3.

 

After   the   water   source   has   been   closed   and   all   residual   water   has   been   purged   from   
the   mainline,   sub-­‐laterals   and   sprinkler   head,   operate   the   sprinkler   head   manually   
from   the   control   product   at   least   4-­‐5   times   for   short   periods   of   time   (less   than   1   
minute)   so   that   any   remaining   water   can   be   flushing   from   the   solenoid   plunger   
chambers.   

4.

 

During   the   winter   it   is   recommended   to   activate   the   solenoid   for   about   1   minute   2   
times   a   week.         

   

7.0   Maintenance   

   

1.

 

Clean   the   interior   cavity   of   the   sprinkler   body   with   an   industrial   vacuum   or   similar   
device   on   an   annual   basis   or   sooner   depending   on   the   application.   

2.

 

Clean   around   the   outer   edge   of   the   sprinkler   body   from   overgrown   grass   in   natural   
turf   applications.   This   may   require   monthly   inspection   and   cleaning   depending   on   
the   season   and   turf   species.   

   

8.0   Inspection   and   Disassembly

   

The   Mirage   M-­‐125   /   M-­‐115   series   sprinklers   are   represent   7   major   subassemblies   noted   as   
follows:   

1.

 

Lid   or   cover   to   the   internal   impact   drive   assembly,   

2.

 

The   main   nozzle   assembly   –   The   size   is   molded   into   the   side   of   the   main   nozzle   and   
in   threaded   into   the   impact   drive   assembly   with   a   ¾”   socket.      Main   nozzles   for   the   
M-­‐125   /   M-­‐115   are   7.0,   8.0,   9.0,   10.0,   11.0,   12.0,   13.0,   14.0,   15.0,   16.0   and   17.50.         

3.

 

The   internal   impact   drive   subassembly   

4.

 

The   upper   portion   of   the   sprinkler   body,      

5.

 

The   solenoid   and/or   decoder   chamber,   

6.

 

The   lower   portion   of   the   sprinkler   body,   

7.

 

The   foot   valve   and   bottom   inlet   screen   subassembly.   

   
Figure   6.1   identifies   these   subassemblies.   
   
   
   
   

Summary of Contents for Mirage M-115

Page 1: ...M 125 M 115 Operating and Maintenance Instructions Underhill International Corporation 20505 Crescent Bay Drive Lake Forest CA 92630 Phone 949 305 7050 Fax 949 305 7051 www uicorp net www underhill us...

Page 2: ...1 DEFINITION OF SYMBOLS 3 2 2 DANGER IF SAFETY INSTRUCTIONS ARE NOT OBSERVED 4 3 0 DESCRIPTION 4 4 0 INSTALLATION 4 5 0 COMMISSIONING 4 6 0 WINTERIZING 5 7 0 MAINTENANCE 5 8 0 INSPECTION AND DISASSEM...

Page 3: ...ull 3600 or part circle to a minimum of 300 The Mirage M 125 M 115 can be applied in both synthetic and natural turf applications Both products have a 1 1 2 BSP inlet threads and can be mated with Und...

Page 4: ...provided PVC or ductile iron swing joint assembly 5 Once the sprinkler head is installed set vertically and to adjacent finish grade Make the wire connections for valve in head models using approved...

Page 5: ...ater can be flushing from the solenoid plunger chambers 4 During the winter it is recommended to activate the solenoid for about 1 minute 2 times a week 7 0 Maintenance 1 Clean the interior cavity of...

Page 6: ...Mirage M 125 M 115 Operating Maintenance Instructions 6 M 125 M 115 Sprinkler Subassemblies Figure 6 1 1 2 3 5 4 6 7...

Page 7: ...s threaded plate to the side 2 Locate and unscrew the slotted head fasteners that secure the impact drive assembly to the lower portion of the sprinkler body Set the fasteners to the side and carefull...

Page 8: ...the valve sleeve tool p n RZK2 17623 Insert into the lower sprinkler body with the chamfered surface pointing downward Grease the rubber edges to ease of insertion 2 Align the valve insert with manua...

Page 9: ...impact drive assembly are set to arc pattern desired 6 Place the brass threaded plate and secure the top lid to the plate using the 2 qty Allen head fasteners 7 Operate the re assembled sprinkler eit...

Page 10: ...is inadequate De pressurize the mainline or sub lateral piping before attempting the last two possible root causes The solenoid is defective The plunger in the solenoid is stuck in the up position Re...

Page 11: ...compressed air blow the control pipe backwards to remove any clogged debris 3 Sprinkler will not turn off manually De pressurize the mainline or sub lateral piping before attempting the last two poss...

Page 12: ...possible root causes The bottom inlet filter is clogged with debris Verify delivery pressure with a Pitot tube and pressure gauge while the sprinkler is operating Is the operating pressure matching t...

Reviews: