background image

9

Removable Upholstered Top (Installation)

Removable Upholstered Top (Removal)

Step 1:

Carefully lay upholstered 

top on table, aligning black 
slide latches on underside 
of upholstery with cutouts 
in support pan.

Step 1:

Grasp slide latch with 
thumb and forefinger.

Step 3:

If latches are not properly 
aligned, slightly raise foot 
section and maneuver 
upholstery slightly until all 
latches align properly.

Step 3:

While pulling toward 

you (away from the 

pan), slide the latch to 
the unlocked position.

Step 5:

Using your index finger, 
slide all four black slide 
latches toward the center 
of the support pan until 
fully engaged. Lower the 
back section.

Step 2:

Slide latches may not be 
perfectly aligned when 
upholstery is resting on 
the support pan. Proceed 
to next step.

Step 2:

Pull the slide latch 

toward you (away 

from the metal pan).

Step 4:

Raise the back section

 

of the upholstery and 
support 

pan (4070-650:)

 

by squeezing the manual 
release lever and gently lifting 
upward. (4040-650:) by using

 

hand or foot control.

Step 4:

Allow the latch to return 
to its normal position. 
Repeat for all latches.

Step 6:

Raise the foot section 

of the upholstery and 

support pan, and repeat 
the step five for the 
remaining four black 
slide latches. Lower

 

the foot section.

FEATURES AND OPERATION

Summary of Contents for 4040-650

Page 1: ...OF MANUFACTURE MAXIMUM PATIENT WEIGHT 650 LBS 295 KG OWNER S MANUAL 4040 650 4070 650 POWER EXAM TABLE UMFmedical com Ph 814 266 8726 Fax 814 266 1870 1316 Eisenhower Blvd Johnstown PA 15904 customerservice umfmedical com ...

Page 2: ...water Ordinary Equipment is not suitable for use in the presence of a flammable anesthetics mixture with air or with oxygen or with nitrous oxide Mode of Operation Continuous operation with intermittent loading 1 minute on 9 minutes off or 2 minutes on 18 minutes off This product has been evaluated with respect to electrical shock fire mechanical hazards only in accordance with UL60601 1 and CAN C...

Page 3: ...al 220V 60HZ 5AMP Power Cord Length 10 FT 3 0m Table Weight 400 lbs 181kg Paper Roll Maximum size 21 0 Long x 3 5 Diameter 53 3 cm x 8 9 cm Storage Drawer Front 19 0 W x 12 0 D x 3 5 H 48 cm x 30 cm x 9 cm Storage Drawer Side 24 5 W x 12 5 D x 3 5 H 62 cm x 32 cm x 9 cm 24 5 12 5 3 5 SPECIFICATIONS 4040 650 ...

Page 4: ...Electrical Supply Optional 220V 60HZ 5AMP Power Cord Length 10 FT 3 0m Table Weight 400 lbs 181kg Paper Roll Maximum size 21 0 Long x 3 5 Diameter 53 3 cm x 8 9 cm Storage Drawer Front 19 0 W x 12 0 D x 3 5 H 48 cm x 30 cm x 9 cm Storage Drawer Side 24 5 W x 12 5 D x 3 5 H 62 cm x 32 cm x 9 cm 24 5 12 5 3 5 ...

Page 5: ...ate all table functions in order to prevent misuse when staff is not present Patient Safety Table Lockout To lock and unlock FOR MAXIMUM PATIENT SAFETY LOCK TABLE IMMEDIATELY AFTER EACH USE WARNING 4040 650 4070 650 Press hold STOP button for 2 seconds 1 beep indicates locked 2 beeps indicates unlocked ...

Page 6: ...6 TABLE BACK Hand Control Foot Control FEATURES AND OPERATION Hand Foot Control Table Operation 4040 650 DO NOT USE BACKREST AS A SEAT WARNING Height Adjustment Backrest Adjustment Home ...

Page 7: ...RES AND OPERATION Hand Control Foot Control DO NOT USE BACKREST AS A SEAT WARNING Height Adjustment Backrest Adjustment Home Back Adjustment Manual Operation 1 Depress release handle 2 Adjust backrest to desired position 3 Release handle to lock TABLE ...

Page 8: ...imultaneous Movement shown as an example 4040 650 4070 650 To Program 1 Move table to desired position for memory storage 2 Press and hold approximately 3 seconds desired memory position button M1 or M2 in which table position is to be stored An audible double beep should be heard indicating table position has been programmed 3 To use memory function press and hold the memory button M1 or M2 for 1...

Page 9: ... all four black slide latches toward the center of the support pan until fully engaged Lower the back section Step 2 Slide latches may not be perfectly aligned when upholstery is resting on the support pan Proceed to next step Step 2 Pull the slide latch toward you away from the metal pan Step 4 Raise the back section of the upholstery and support pan 4070 650 by squeezing the manual release lever...

Page 10: ...e two pins toward the front of the leg section 2 Lift the front of the leg pad until it clears the two pins and pull the leg pad forward 3 Lower the front of the leg pad The two pins will enter slots located on the bottom of the leg pad preventing movement DO NOT USE THE LEG REST TO SUPPORT PATIENT S ENTIRE WEIGHT WARNING WITH LEG REST PAD IN TILTED POSITION THE FRONT SLIDE PINS ON PAD MUST SEAT A...

Page 11: ...nd reinstall into brackets 1 Pull the stirrups out and unfold 2 Lift slightly and move left or right to position 3 Release stirrup to lock into position 1 Lift up seat section and flip the pelvic support arm 2 Place seat section down to secure the mechanism DO NOT SUPPORT THE PATIENT S ENTIRE WEIGHT WITH THE STIRRUPS WARNING FEATURES AND OPERATION ...

Page 12: ...e panels Step 3 Slide cages to opposite side of table Step 5 Install side panel on opposite side Step 2 Remove drawer Extend drawer Press tabs on both sides Remove drawer Step 4 Align slides and install drawer on opposite side Slide in until an audible click is heard ...

Page 13: ... PATIENT READY POSITION PRIOR TO A PATIENT ACCESSING TABLE LOW GROUND CLEARANCE WHEN TABLE IS ENGAGED IN CLEANING POSITION AVOID ROLLING TABLE OVER OBJECTS GREATER THAN 25 HIGH OR DAMAGE MAY OCCUR TABLE IS NOT TO BE USED FOR PATIENT TRANSPORT CASTERS ARE TO BE USED SOLELY WHEN MOVING TABLE WITHIN THE EXAMINATION ROOM TO FACILITATE CLEANING UNDERNEATH THE TABLE CASTERS ARE NOT TO BE USED DURING INS...

Page 14: ...ETY REQUIREMENT OF THIS EQUIPMENT MAY LEAD TO A REDUCED LEVEL OF SAFETY OF THE RESULTING SYSTEM OUTLET IS FOR MEDICAL EQUIPMENT ONLY CAUTION CHECK GROUND CONTINUITY PERIODICALLY 120V MAXIMUM OUTPUT 5 0A 120V 220V MAXIMUM OUTPUT 2 5A 220V WARNING DO NOT DISCARD COVER COVER IS TO BE REAPPLIED AFTER REMOVAL OF EQUIPMENT FROM MULTIPLE SOCKET OUTLET WARNING WARNING GROUND RELIABILITY CAN ONLY BE ACHIEV...

Page 15: ...tirrups to full extended position with heel stirrup in retracted position 2 Insert knurled end of knee crutch rod into hole on end of stirrup 3 Adjust to position and tighten with slide lock The stainless steel drain pan is offered without a spout standard or with spout optional shown left for the procedure that you need ...

Page 16: ...union nut clockwise until fully threaded Union nut has a slit in it to allow for easy threading ATTENTION If hand control will be primary control used UMF Medical recommends the hand control to be plugged into the front of the table Back Left to Right 1 Port for foot control 2 Port for hand control 3 LED 4 Port for power cord Front 1 Optional port for foot or hand control ...

Page 17: ...e Facilities for bleach alternative cleaners Note Immediately remove any fluid spilled on upholstery surface Antimicrobial UMF Medical Upholstery providers outstanding protection in difficult medical and healthcare environments and contains an agent effective against bacterial and fungal microorganisms Contact UMF Medical Customer Service 1316 Eisenhower Blvd Johnstown PA 15904 Toll Free 1 800 638...

Page 18: ...tions caused in whole or in part by mishandling misuse abuse negligence alteration accident freight damage tampering or failure to seek and obtain repair or replacement in a timely manner Products which are not installed used and properly cleaned and maintained as required in the UMF Medical installation and or Owner s Manual for the applicable product Replacement parts alterations or installation...

Page 19: ...TELY to ensure that your table functions properly PLEASE DO NOT PLUG TABLE IN UNTIL PRECEDING STEPS ARE COMPLETED 1 The table has three 3 ports for the hand and foot control in the table base two 2 located at the rear and one 1 located at the front 2 Locate the ports and choose which ports you prefer to place hand an foot controls 3 Start with installing the hand control 4 Locate the green dot on ...

Reviews: