21

Recalibration

1.

To recalibrate the device, you need an additional remote control or an
additional SensoCommander (except SensoCommander Classic). Position
one SensoCommander at the height of reference point A2 (see the two
previous pages). Then perform calibration with the other.

2.

During calibration, pay attention to the alignment of the DuraMax and
the displays for the X and Y axes (E, I). Always calibrate both axes. You
can switch between axes with button 14 of the additional remote control
or SensoCommander.

3. Set the device to calibration mode:

Switch off the DuraMax, and then, with the auto/man button (J) depres-
sed, switch on again (briefly press ON/OFF button (G). Keep the auto/man
button (J) depressed until the tilt display (C) lights up. When this happens,
the auto/man button (J) can be released.

4. Correcting calibration:

Using button 15 of the additional remote control or SensoCommander,
move the laser from its present position to the height of reference point
A2.

5. Ending calibration:

Cancel: By switching off the DuraMax, the entire calibration is rejected

and the previous status restored.

Save:

The new calibration can be saved by pressing button 17 of the
additional remote control or SensoCommander.

X

Y

X- / Y- axis

Note:

Regularly check the calibration

before use, after transport and after
extended periods of storage. Always
make sure to control all axes. See
also "General safety information" on
page 13.

Summary of Contents for LaserLiner DuraMax

Page 1: ...96 02 1 Rev 05 07 GB D NL F DK E Bedienungsanleitung Operating instructions Gebruiksaanwijzing Betjeningsvejledning Mode d emploi Instrucciones para su uso K ytt ohje 3 12 13 22 23 32 33 42 43 52 53...

Page 2: ...2 DuraMax...

Page 3: ...and after extended periods of storage We also wish to point out that absolute calibration is only possible in a specialist workshop Calibration by yourself is only approximate and the accuracy of the...

Page 4: ...Y axis display F Operating Battery display G ON OFF button H Receiver window for remote control A B F G I J I X axis display J Auto man button K Battery compartment L 5 8 thread bottom M Battery char...

Page 5: ...x ENGLISH 1 IR output signal 2 Receiver field for laser beam 3 SpotLite marking LED 4 LED display 5 Vial 6 Securing screw 7 Universal mount 8 Securing lever 9 Battery compartment on back 10 Control pa...

Page 6: ...ter the instrument has been switched on the ADS is not active In order to protect the instrument from position changes caused by external influences the ADS has to be activated by pressing the push bu...

Page 7: ...y the installation symbols Ensure the polarity is correct If the LED F blinks constantly either the batteries must be exchanged or recharged Insertion of batteries in the SensoCommander Remove the bat...

Page 8: ...n aincline press the auto man J button The X axis can now be adjusted and the X axis display I lights up To adjust the inclination of the Y axis press the tilt button D the Y axis display E lights up...

Page 9: ...ment by hand Control panel SC 120 Pro 14 Switchover between X and Y axes in tilt or calibration mode 15 Sound volume axis adjustment in tilt or calibration mode 16 Hand receiver mode 17 Save calibrati...

Page 10: ...pot mode 2 Turn the device through 180 and mark point A2 You now have a hori zontal reference between points A1 and A2 Performing the calibration check 3 Position the device as near as possible to the...

Page 11: ...o man button J depres sed switch on again briefly press ON OFF button G Keep the auto man button J depressed until the tilt display C lights up When this happens the auto man button J can be released...

Page 12: ...n rechargeable battery life approx 90 h 4 x Typ D Mono 1 5V Battery recharging time approx 14 h Battery recharging time 10 C 50 C Weight 3 kg SensoCommander Optional Batteries Power supply SC Pro 200...

Page 13: ...73 DuraMax...

Page 14: ...74 DuraMax...

Page 15: ...e typer Accessoires en option E I PL FIN Accesorios opcional Accessori optional Akcesoria opcja Lis mahdollisuuksia valinnaisvarusteilla Acess rios opcional Art Nr 080 50 Art Nr 080 33 Art Nr 035 00 A...

Page 16: ...Versand Anschrift Service Telefon 49 2932 638 486 Fax 49 2932 638 489 Service and Shipping Address Service phone 49 2932 638 300 Fax 49 2932 638 333 Service en verzendadres Servicetelefoon 49 2932 63...

Reviews: