ULVAC CRYOGENICS INCORPORATED
1.3 Specifications
Table 1-1 Shows the specifications of GN-30i.
Table 1-1 GN-30i Specifications
Items
Specifications
Model
GN-30i
Purity (*1)
99 vol%
N2 production rate (*2)
30 NL/min
Discharge pressure
0.2 MPa
Dewpoint
Below -60
°C
Flow meter (*3)
50.0 NL/min
Electrical rating
Voltage and frequency
Main power source 200VAC (single-phase) 50/60Hz
Power consumption
1200W
Operating method
Input operation signals
Input and output
electrical signals
Input
Remote signal: CLOSE while in operation
Contact capacity:DC30V 20mA required
Output
Running signal: In operation (ON)
N2 supply signal: While supplying (ON)
Alarm signal: While in alarm state (ON)
Relay contact output: Continuous load current 100VAC
below 1A
Drained water
processing
Evaporation inside the equipment
Nitrogen gas exit
φ
6 easy coupling
Ambient
temperature(*4)
5 - 40
°C
Ambient humidity(*4)
10 - 80%RH
Dimensions
600(W) x 650(D) x 1,300(H) (excluding casters)
Weight
Approx. 120Kg
Color
DIC 546 1/2
Compressor
2688CS32-273 (made by Thomas) x 3
Noise level
60dB(A)
When measured from front 1m and height 1m
*1
Purity of N
2
(nitrogen) + Ar(argon).
*2
This is the volume measured at the ambient conditions of temperature 20°C and
humidity 60% RH and converted to 0°C and atmospheric pressure. The production
volume above is the maximum generation rate under the conditions of temperature 20°C
and humidity 60% RH and filters are cleared. The production rate decreases when
depending on the conditions such as temperature or humidity.
*3
Flow meter is made to fit the above discharge pressure. If it is used at the pressure
other than the above, conversion is needed.
*4
This is not to guarantee the performance under these conditions.
Summary of Contents for GN-30i
Page 2: ......
Page 6: ...IV ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...
Page 10: ...4 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...
Page 26: ...20 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...
Page 28: ...CS 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...
Page 30: ...R 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...