Power Consumption: 

 

 

Model 

Power 

Consumption

 

SS-10, SV-10, ME-10 

25 Watts (.22 A @ 115VAC) 

SS-20, SV-20, ME-20 

40 Watts (.35 A @ 115VAC) 

 
Replacement Parts: 
 

Model Description

 

Replacement Part Number 

SS-10, SV-10, ME-10 

Replacement Aquatronic – 10 Lamp 

LP-PP-0021 

SS-10, SV-10, ME-10 

Replacement Aquatronic – 10 Quartz 

QZ-OH-0020 

SS-20, SV-20, ME-20 

Replacement Aquatronic – 20 Lamp 

LP-PP-0023 

SS-20, SV-20, ME-20 

Replacement Aquatronic – 20 Quartz 

QZ-OH-0021 

RB-PP-0004 

EPDM HI-TEM O-Ring for sealing of the 

Quartz Sleeve 

RB-PP-0004 

 

Warranty:                      

 
Ultravation warrants this product against any defects in material or workmanship for a period of 2 years after date of 
consumer purchase, with the exception of the Ultraviolet Lamp, which is warranted for a period of 90 days after date of 
consumer purchase. 
 
This warranty does not include damage to the unit from accident, misuse or improper installation.  If this product should 
become defective during the warranty period, Ultravation will elect to repair or replace the product free of charge. 
 
This warranty shall be void if the ultraviolet sterilizer is moved from a place or original installation, or if damage is caused by 
misuse, misapplication, accident, freezing, flood, fire, or if not installed in accordance with instructions furnished by 
Ultravation Inc. 
 
This warranty shall be void in the event of damages from external sources or where the ultraviolet sterilizer has been 
operated at pressure in excess of 100 pounds per square inch or at a temperature in excess of 100 degrees F., or below 32 
degrees F.  Incidental costs or consequential damages are not covered by this warranty. 
 
Ultravation will return repaired or replaced warranted products pre-paid, provided that the product was delivered pre-paid.  
Ultravation shall have no responsibilities for charges incurred by the customer for installation or removal of warranted items.  
Liability is limited only to the replacement or repair of this product 
 
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. 
All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation, Inc. 
 
Ultravation, Inc. ~ P.O. Box 165 ~ 212 Ideal Way ~ Poultney, Vermont 05764 
Phone: 802-287-9735 ~ Fax: 802-287-9203 ~ 

www.ultravation.com

 

 

Summary of Contents for Aquatronic SS-10

Page 1: ...and O Ring Installation Page 4 Germicidal Lamp Installation UVC Sensor Installation FOR ME SERIES ONLY Filling the UV Unit with Water Disinfecting the Piping System with Chlorine Final Check Page 5 Annual Maintenance Procedure 9000 Hour Timer Reset FOR SV SERIES ONLY UVLampMonitor FOR SV SERIES ONLY Page 6 UV Power Consumption Replacement Parts Warranty Page 7 Recommended Installation Diagram LEAV...

Page 2: ...o Polished 304SS Vessel UVC Lamp Quartz Sleeve Clear Compression Nut Quartz O Ring and Silicone Top Bracket Locking Nut Upper Bracket Lower Bracket UVC Warning Label Warranty Card ME Series has a UVC Sensor Cord assembly in addition to the parts listed above Safety Precautions It is recommended that this unit be installed and maintained by a trained technician WARNING UV Hazard Always protect eyes...

Page 3: ... 1 The ultraviolet unit is designed to be installed in a vertical position The unit is supplied with 2 brackets to support the unit NOTE The upper bracket has a grounding lug attached to it 2 Place the top bracket larger one over the nipple located at the top of the vessel The end of the bracket with the three holes should be facing up towards the top of the vessel 3 Tighten the gray PVC ring onto...

Page 4: ...2 Make sure the Aquatronic UV unit is plugged into a surge protector not provided then a dedicated electrical outlet with power 24 hours per day 3 Check all piping for leaks repair if necessary 4 Open cold water lines and flush out until chlorine odor is no longer detected Before consumption of water an EPA Lab Test is suggested Germicidal Lamp Installation 1 Clean the germicidal lamp with househo...

Page 5: ...tained replace Reference Quartz Installation 8 Follow with germicidal lamp installation 9000 Hour Timer Reset FOR SV SERIES ONLY It is recommended to reset the 9000 hour timer after replacing the germicidal lamp 1 Make sure the electrical power cord is removed from the electrical outlet 2 Remove power supply cover 3 The battery which operates the 9000 hour timer during a power outage should be cha...

Page 6: ...l be void if the ultraviolet sterilizer is moved from a place or original installation or if damage is caused by misuse misapplication accident freezing flood fire or if not installed in accordance with instructions furnished by Ultravation Inc This warranty shall be void in the event of damages from external sources or where the ultraviolet sterilizer has been operated at pressure in excess of 10...

Page 7: ......

Reviews: