background image

 

 

www.ultravation.com 

5

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

UVCMONITOR (FOR ME SERIES ONLY) 

 

The digital display shows the percent UVC output 
based on a new UVC lamp.  The output needs to be 
calibrated after 100 hours of use.  This allows the 
lamp output to stabilize.   
 

After 100 hours of operation the SCALE 
adjustment – on the right side of the control box – 
must be adjusted until the percent output = 100. 
 

ANNUAL MAINTENANCE PROCEDURE: 

 
Annual Germicidal Lamp Replacement and Quartz 
Cleaning: 

 
1.  Unplug the power supply from surge protector and 

the electrical outlet. 

2.  Pull the black cap from the center of the clear 

gland nut. 

3.  Carefully lift the germicidal lamp out of the quartz 

sleeve by pulling up on the gray harness wire and 
discard the lamp. Remember the lamp is glass 
and can cause injury to you if the lamp is 
dropped. 

4.  Open the boiler drain on outlet side of UV unit to 

depressurize vessel. When completed, close 
boiler drain. 

5.  Carefully remove clear gland nut, gently grasp 

quartz sleeve and lift out. 

6.  Remove clear gland nut and O-ring from quartz 

sleeve. 

7.  Clean quartz sleeve with household alcohol. If 

stained, replace. 

 
(Reference Quartz Installation) 
 

8.  Follow with germicidal lamp installation. 

 
 
 

 
 
 
 

 

9000 Hour Timer Reset (FOR SV SERIES ONLY): 
 
It is recommended to reset the 9000 hour timer after 
replacing the germicidal lamp. 
 

1. 

Make sure the electrical power cord is removed from 
the electrical outlet. 

2. 

Remove power supply cover. 

3. 

The battery which operates the 9000 hour timer during 
a power outage should be changed annually with a 
CR2032 (3V) battery or equivalent. To remove old 
battery, pull it up and away from the battery harness 
located on the right side of circuit board. 

 

When installing the new battery, make sure the “+” side of the 
batter is viewable. 

Locate the brown reset button on the lower center portion of 
the green circuit board, to the left of the battery. 
 
1. 

Once located, hold reset button for 5 seconds and 
release. 

2.

 

Re-install the power supply cover and plug electrical 

power cord into the dedicated outlet

.

 

UVLampMonitor (FOR SV SERIES ONLY): 

 

LED 

Color

 

Audible       

Visual Alarm

 

Unit 

Status

 

Green

 

No audible 

 

OK 

Solid Red 

 

No Audible 

Reset lamp service 

indicator or replace lamp 

within 30 days 

Pulsing Red 

(Every 5 

seconds)

 

Beep every 

60 Minutes 

Lamp has exceeded 1 

year of operation reset 

or replace lamps 

Flashing Red 

(Every 1 second)

Beep every  

1 second 

UV lamp(s) are not lit 

 

Summary of Contents for Aquatronic SS-10

Page 1: ...and O Ring Installation Page 4 Germicidal Lamp Installation UVC Sensor Installation FOR ME SERIES ONLY Filling the UV Unit with Water Disinfecting the Piping System with Chlorine Final Check Page 5 Annual Maintenance Procedure 9000 Hour Timer Reset FOR SV SERIES ONLY UVLampMonitor FOR SV SERIES ONLY Page 6 UV Power Consumption Replacement Parts Warranty Page 7 Recommended Installation Diagram LEAV...

Page 2: ...o Polished 304SS Vessel UVC Lamp Quartz Sleeve Clear Compression Nut Quartz O Ring and Silicone Top Bracket Locking Nut Upper Bracket Lower Bracket UVC Warning Label Warranty Card ME Series has a UVC Sensor Cord assembly in addition to the parts listed above Safety Precautions It is recommended that this unit be installed and maintained by a trained technician WARNING UV Hazard Always protect eyes...

Page 3: ... 1 The ultraviolet unit is designed to be installed in a vertical position The unit is supplied with 2 brackets to support the unit NOTE The upper bracket has a grounding lug attached to it 2 Place the top bracket larger one over the nipple located at the top of the vessel The end of the bracket with the three holes should be facing up towards the top of the vessel 3 Tighten the gray PVC ring onto...

Page 4: ...2 Make sure the Aquatronic UV unit is plugged into a surge protector not provided then a dedicated electrical outlet with power 24 hours per day 3 Check all piping for leaks repair if necessary 4 Open cold water lines and flush out until chlorine odor is no longer detected Before consumption of water an EPA Lab Test is suggested Germicidal Lamp Installation 1 Clean the germicidal lamp with househo...

Page 5: ...tained replace Reference Quartz Installation 8 Follow with germicidal lamp installation 9000 Hour Timer Reset FOR SV SERIES ONLY It is recommended to reset the 9000 hour timer after replacing the germicidal lamp 1 Make sure the electrical power cord is removed from the electrical outlet 2 Remove power supply cover 3 The battery which operates the 9000 hour timer during a power outage should be cha...

Page 6: ...l be void if the ultraviolet sterilizer is moved from a place or original installation or if damage is caused by misuse misapplication accident freezing flood fire or if not installed in accordance with instructions furnished by Ultravation Inc This warranty shall be void in the event of damages from external sources or where the ultraviolet sterilizer has been operated at pressure in excess of 10...

Page 7: ......

Reviews: