During the working process, the system will continuously monitor the temperature of the

power inverter part of the generator to ensure that it can prevent further temperature rise and

damage the equipment in time when the temperature is too high. The design has fully taken

into account the temperature generation and heat dissipation, and this protection does not

occur under normal circumstances.
When this prompt occurs, try:

Improve the use environment, increase heat dissipation space or provide external heat

dissipation.

Check if the vents are blocked and the fans are not damaged.

Wait a few minutes for the temperature to drop, and then restart the machine to continue

working.

6.5 Error: IGBT overcurrent protection

This protection indicates that some reasons have caused a very large power consumption of

the whole machine, which has exceeded more than twice the rated power in a short period of

time. Special care should be taken.
When this prompt occurs, try:

Check whether the frequency is correct. Under no-load conditions, set the frequency of

chasing frequency to a relatively high value, such as 20.4k for 20k models, and perform

frequency search.

Check if the mold is damaged. Disassemble the mold or replace it with a mold that is

confirmed to be good and check again.

Whether the load is short-circuited. Check whether there is a short-circuit or insufficient

voltage resistance of the load connecting wires and plugs that cause short-circuit overcurrent

protection.

Other issues that can cause severe over power consumption.

6.6 Error: load overcurrent

The system detects that the load current exceeds the internally set protection current value.
When this prompt occurs, you can try:

Check if the load is too heavy. Reduce load
For overcurrent caused by excessive load, you can appropriately increase the amplitude

and output the same power by increasing the driving voltage to reduce the driving current, but

this will more easily cause a warning of excessive load power consumption and have a greater

impact on the life of the mold Big.

If there is no sound wave output, check the load line for short circuit.
Increase the frequency by 0.1khz, try again

6.7 Error: load overvoltage

The system detects that the load voltage exceeds the internally set protection voltage value.
When this prompt occurs, you can try:

Reduce the amplitude to reduce the drive voltage.
Check if the load is not connected.
Check whether the utility power is serious.

Summary of Contents for JYD-2700S

Page 1: ...anual I Basic information introduction II Environment Requirements III Connecting ports introduction IV Display interface and parameter introduction V The most common setup process for welding applica...

Page 2: ...ght 7KG Color light grey Features Automatic frequency tracking The system automatically tracks the resonance frequency of the welding head Compensate for detuning caused by heat and other reasons Digi...

Page 3: ...ature 25 C to 70 C Relative temperature 30 to 90 without condensation warning To ensure that the ultrasonic generator has good ventilation care must be taken not to cover the generator s ventilation o...

Page 4: ...7 8 can share a line Attention The power plug must be inserted into a socket with a ground terminal The adaptable power supply range of the ultrasonic signal generator is 220VAC 10 50 60Hz By adjusti...

Page 5: ...utput power of the whole machine Production Used to record production yield Only the number of times the entire welding process has been performed is recorded Emergency stops during the welding proces...

Page 6: ...whether the power is within 500W and whether the sound is mainly based on crisp model frequency sounds If you report an error that is out of range you should check the mold or transducer for abnormal...

Page 7: ...the horn with a ratio of 1 2 or less This is what we recommend The traditional 1 3 horn is more suitable for traditional self excitation ultrasound Re search the resonance frequency and set the freque...

Page 8: ...ls and perform frequency search Check if the mold is damaged Disassemble the mold or replace it with a mold that is confirmed to be good and check again Whether the load is short circuited Check wheth...

Page 9: ...or 24V 5V 3V3 etc The system detects that the core voltage is not within the set range When this prompt occurs try Contact us If you still cannot find the cause after above testings please contact us...