Warning
When the automatic mode is selected: the interface provides a prompt of the current working status
(in the above figure, the yellow background running word indicates that it is in work). When it
displays as running, it indicates that the sound wave is being output. At this time, be careful, if the
belt is cutting The knife mold should avoid touching the tip of the knife.
Warning
In the case of continuous work (welding time exceeds 5S), it should be ensured to work at a lower
power. It is recommended to use less than 1/3 of the model power (such as 2000W models,
continuous work should not exceed 666W as much as possible). In order to prevent excessive heat
generation, extend the life of the mold, continuous output power can be appropriately increased
under enhanced heat dissipation conditions.
Amplitude
: Adjust the load vibration intensity by adjusting the voltage value output to the
load, ranging from 1% to 100%.
Frequency
: the current output frequency of the ultrasonic generator (when the ultrasonic
output is not turned on, it is displayed as the standby start frequency)
Current
: display the current of the ultrasonic transducer.
Power
:The output power of the whole machine.
Production
: Used to record production/yield. Only the number of times the entire welding
process has been performed is recorded. Emergency stops during the welding process are
not recorded. Can only be cleared, the maximum record is 99999. If you need to record, it is
recommended to clear it every day before use.
Ultrasonic test
: The maximum amplitude of the sonic test is 40% of the total amplitude. Even if
your setting exceeds 40, if you want to exceed 40% of the output, you must use an external start. The
purpose of this is to protect the mold to a certain extent to prevent irreversible damage caused by
direct driving with large amplitude when the mold is abnormal (such as not being locked).
4.2 Use of automatic frequency tracking function:
Auto-Freq:
Search for mold resonance frequency. After setting a frequency sweep
starting frequency, click to start the search and the system will automatically find the best
resonance frequency.
If you replace a new set of load (including transducer / amplifier / mold or their combination),
you should re-run the automatic frequency search to obtain the working frequency, or
manually enter the automatic frequency tracking interface and press "Start "Search, if the
report is out of" Out of DAC fine-tuning range error ", it means that the system cannot find a
working frequency point.