background image

H1

L2

TC

L1

HI  OUTER HEATING ELEMENT 4.9KW

TC  TEMPERATURE CONTROLLER

L2  RED INDICATOR LAMP

L1  AMBER INDICATOR LAMP

S1  TOGGLE ON/OFF SWITCH

S1

208/240V

WIRING DIAGRAM -

 Since minor wiring changes may occur in the future, 

USE 

the diagram pasted to the

Control Panel Access Door for circuit tracing and/or trouble-shooting a Rethermalizer.

15

ELECTRIC MODEL REO-1620SE RETHERMALIZER

REPLACEMENT PARTS

       NUMBER  

   PART 

 

    PN   

 

       DESCRIPTION

LEVER 

12A510 

DRAIN BALL VALVE

SWITCH 

18A048 

120 VOLT TOGGLE ON/OFF DPST

GUARD 

18-129 

ON/OFF SWITCH

ELEMENT 

18A297 

208 VOLT 4.9 KW 

OUTER 

ELECTRIC HEAT

 

 

18A299 

240 VOLT 4.9 KW 

OUTER 

ELECTRIC HEAT

THERMOSTAT 

22A148 

30 AMP, 120-277 VAC, 2 POLE 60ºF (16ºC) TO

 

 

 

250ºF (121ºC)

*10 

BASKET 

19A475 

61⁄2” (165mm) x 18” (457mm) x 12” (305mm)   

 

 

 

DEEP S/S CHUB 

11 

FOOT 

22-022 

ADJUSTABLE S/S BULLET

*12 

GRILL 

19A880 

TUB 161⁄2” (419mm) x 181⁄2” (470mm) 3” (76mm) HIGH

14 

SECTION 

23-015 

ELECTRICAL TERMINAL

15 

SNAPLIGHT 

60-094 

240 VOLT 1/3 WATT W/RED LENS

16 

SNAPLIGHT 

23-342 

240 VOLT 1/3 WATT W/AMBER LENS

19 

VALVE 

24A057 

11⁄4” (32mm) CHROME DRAIN BALL

20 

TEE 

24A060 

11⁄4” (32mm) x 11⁄4” (32mm) x 

3

/

4

” (19mm) FPT 

 

 

 

GALVANIZED 

        

*          NOT SHOWN

Summary of Contents for ULTRATHERM REO-1620SE

Page 1: ...9 San Antonio Texas 78201 800 525 8130 210 731 5000 FAX 210 731 5099 MODEL REO 1620SE ULTRATHERM ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS Ultrafryer Systems is a wholly owned subsidiary of Stande...

Page 2: ...ain the Electric Model REO 1620SE Rethermalizer Proper use of this manual will allow store employees to properly operate clean and maintain this equip ment which will reduce service call expenses TECH...

Page 3: ...eaning 6 Model REO 1620SE Electric Rethermalizer Operation General 8 Cooking Procedures 8 Preventive Maintenance Troubleshooting and Cleaning Preventive maintenance 10 Troubleshooting Chart 10 Cleanin...

Page 4: ...WARRANTY INFORMATION 1...

Page 5: ...s including but not limited to any loss in store sales spoiled food products transportation duty or custom cost or failure damage to component parts due to scaling caused by hard water This does not c...

Page 6: ...3 GENERAL INFORMATION...

Page 7: ...E RETHERMALIZER TABLE MODEL REO 1620SE RETHERMALIZER The Electric Model REO 1620SE Rethermalizer was designed by Ultrafryer Systems to operate as a com mercial warmer to thaw heat and hold frozen prod...

Page 8: ...INSTALLATION AND INITIAL CLEANING 5...

Page 9: ...s follows a Ensure the controls listed below are in the proper position APPLICABLE CIRCUIT BREAKER IS ON ELECTRICAL PLUG IS CONNECTED TO THE ELECTRICAL WALL RECEPTACLE WATER SHUT OFF VALVE IS OPEN DRA...

Page 10: ...MODEL REO 1620SE RETHERMALIZER OPERATION 7...

Page 11: ...OFF indi cating water is at the desired COOK tempera ture 1 place the PRODUCT to be cooked into the Rethermalizer Tub and 2 set an indepen dent TIMER to the desired COOK TIME A When product is placed...

Page 12: ...PREVENTIVE MAINTENANCE TROUBLE SHOOTING AND CLEANING 9...

Page 13: ...for damage If applicable order replace ment item Drain lever X Inspect the drain lever for free move ment and check for accumulation of debris NOTE As mentioned previously it is ESSENTIAL that the Ret...

Page 14: ...ets and grill from the Rethermalizer tub wash them with dish wash solution THOROUGHLY rinse and allow these items to air dry 3 Clean the Rethermalizer tub with dish wash solution THOROUGHLY rinse and...

Page 15: ...TECHNICALASSISTANCE ORDERING INFORMATION AND PARTS IDENTIFICATION 12...

Page 16: ...cument to facilitate filing of freight claims Carriers must be notified immediately and freight inspections must be requested from the carrier Ultrafryer Systems can and will gladly assist you in prep...

Page 17: ...ELECTRIC MODEL REO 1620SE RETHERMALIZER REPLACEMENT PARTS FRONT VIEW LOWER FRONT VIEW WITH FRONT PANEL OPEN LOWER REAR VIEW WITH TERMINAL PANEL OPEN 14...

Page 18: ...2 SWITCH 18A048 120 VOLT TOGGLE ON OFF DPST 3 GUARD 18 129 ON OFF SWITCH 7 ELEMENT 18A297 208 VOLT 4 9 KW OUTER ELECTRIC HEAT 18A299 240 VOLT 4 9 KW OUTER ELECTRIC HEAT 9 THERMOSTAT 22A148 30 AMP 120...

Reviews: