A.  PREVENTIVE MAINTENANCE AND INSPECTION REQUIREMENTS

 

Although the Rethermalizer only requires minimal preventive maintenance, the need to keep it clean cannot be 

 

over-stressed.  The tub, basket, and grill come in contact with food and 

MUST

 be 

THOROUGHLY

 cleaned 

 

each evening.  If the Rethermalizer is kept clean and if the following inspections are performed, this unit will 

 

provide many years of trouble free service.

INSPECTION REQUIREMENTS

INSPECTION INTERVAL

 

ITEM   

 

DAILY 

    WEEKLY  MONTHLY            INSPECT FOR

     Electrical plug, cord and            X 

 

Inspect the  electrical cord, plug and

  ON/OFF switch 

             ON/OFF switch for any physical   

   

             damage.  Replace damaged item

  Chub Basket and Grill                                                                       X               Inspect the Chub Basket and Grill for   

   

             damage.  If applicable order replace-

   

 

ment item.

  Drain lever                                                                 X 

 

Inspect the drain lever for free move-

   

 

ment, and check for accumulation of 

   

 

debris.

 

NOTE: 

  As mentioned previously, it is 

ESSENTIAL

 that the Rethermalizer be kept 

CLEAN

 throughout the day

         and 

THOROUGHLY CLEANED

 at store closing each day.

B.   TROUBLE SHOOTING CHART

 

        PROBLEM 

 

  PROBABLE CAUSE 

 

  CORRECTIVE ACTION

 

1.  No power to the Unit. 

a.  Circuit breaker in the main   a.  Reset circuit breaker and check for cause

 

 

  

 

electrical panel tripped. 

     that made breaker trip 

 

 

 

 

 

b.    Amber Lamp is not on. 

b.   Lamp is burned out; Replace lamp.

 

 

.   

c.    Defective ON/OFF switch 

c.  Replace the ON/OFF switch 

 

 

 

d.   Power Cord not in Electrical  d.  Ensure Plug on end of Power Cord is 

 

 

     

 

Receptacle 

      connected to the Electrical Receptacle.

 

2.  Water is not heated. 

a.    Defective temperature  

a Replace temperature controller probe

 

 

 

 

controller probe

 

 

 

 

b.   Defective heat element 

b.  Replace heat element

10

Summary of Contents for ULTRATHERM REO-1620SE

Page 1: ...9 San Antonio Texas 78201 800 525 8130 210 731 5000 FAX 210 731 5099 MODEL REO 1620SE ULTRATHERM ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS Ultrafryer Systems is a wholly owned subsidiary of Stande...

Page 2: ...ain the Electric Model REO 1620SE Rethermalizer Proper use of this manual will allow store employees to properly operate clean and maintain this equip ment which will reduce service call expenses TECH...

Page 3: ...eaning 6 Model REO 1620SE Electric Rethermalizer Operation General 8 Cooking Procedures 8 Preventive Maintenance Troubleshooting and Cleaning Preventive maintenance 10 Troubleshooting Chart 10 Cleanin...

Page 4: ...WARRANTY INFORMATION 1...

Page 5: ...s including but not limited to any loss in store sales spoiled food products transportation duty or custom cost or failure damage to component parts due to scaling caused by hard water This does not c...

Page 6: ...3 GENERAL INFORMATION...

Page 7: ...E RETHERMALIZER TABLE MODEL REO 1620SE RETHERMALIZER The Electric Model REO 1620SE Rethermalizer was designed by Ultrafryer Systems to operate as a com mercial warmer to thaw heat and hold frozen prod...

Page 8: ...INSTALLATION AND INITIAL CLEANING 5...

Page 9: ...s follows a Ensure the controls listed below are in the proper position APPLICABLE CIRCUIT BREAKER IS ON ELECTRICAL PLUG IS CONNECTED TO THE ELECTRICAL WALL RECEPTACLE WATER SHUT OFF VALVE IS OPEN DRA...

Page 10: ...MODEL REO 1620SE RETHERMALIZER OPERATION 7...

Page 11: ...OFF indi cating water is at the desired COOK tempera ture 1 place the PRODUCT to be cooked into the Rethermalizer Tub and 2 set an indepen dent TIMER to the desired COOK TIME A When product is placed...

Page 12: ...PREVENTIVE MAINTENANCE TROUBLE SHOOTING AND CLEANING 9...

Page 13: ...for damage If applicable order replace ment item Drain lever X Inspect the drain lever for free move ment and check for accumulation of debris NOTE As mentioned previously it is ESSENTIAL that the Ret...

Page 14: ...ets and grill from the Rethermalizer tub wash them with dish wash solution THOROUGHLY rinse and allow these items to air dry 3 Clean the Rethermalizer tub with dish wash solution THOROUGHLY rinse and...

Page 15: ...TECHNICALASSISTANCE ORDERING INFORMATION AND PARTS IDENTIFICATION 12...

Page 16: ...cument to facilitate filing of freight claims Carriers must be notified immediately and freight inspections must be requested from the carrier Ultrafryer Systems can and will gladly assist you in prep...

Page 17: ...ELECTRIC MODEL REO 1620SE RETHERMALIZER REPLACEMENT PARTS FRONT VIEW LOWER FRONT VIEW WITH FRONT PANEL OPEN LOWER REAR VIEW WITH TERMINAL PANEL OPEN 14...

Page 18: ...2 SWITCH 18A048 120 VOLT TOGGLE ON OFF DPST 3 GUARD 18 129 ON OFF SWITCH 7 ELEMENT 18A297 208 VOLT 4 9 KW OUTER ELECTRIC HEAT 18A299 240 VOLT 4 9 KW OUTER ELECTRIC HEAT 9 THERMOSTAT 22A148 30 AMP 120...

Reviews: