5.3 Configuring the UF 831
The configuration for the flow meter is divided into three levels:
Simple: simplified configuration for basic use of the flow meter.
Normal: configuration allowing more detailed use.
Advanced: mode allowing the complete adjustment of the flow meter settings. This mode is
reserved for users with detailed knowledge of the transit time difference flow measuring technique
and with some idea of hydraulic concepts.
The level can be changed by going to the menu Configuration / Settings / Simple, Normal or Advanced:
This menu is also used to activate functions such as
the logger,
the inputs/outputs,
the totalizers.
To activate these options, place the cursor on the line corresponding to the required option and use the <
and > keys.
5.3.1 Flow meter menu
Depending on the type of flow meter and the configuration (simple, normal or advanced) selected, the flow
meter menu may change. Below is a non-exhaustive list of the sections for the flow meter:
CONFIGURATION: configuration of the operating modes, the registration name, the JBUS
characteristics; configuration management, etc.
PIPE / FLUID SETTINGS: setting of the type of fluid, the pipe, the chords, the geometry of the
chords of the measuring point, etc.
DESCRIPTION OF SECTION SETTINGS: settings of the section of the channel or the river.
LEVEL SETTINGS: settings of the level measurement(s).
HYDRAULIC PROFILE: settings of the hydraulic profile curve that the flow meter must use.
HEIGHT/VELOCITY (SPEED) SETTINGS: settings of the height/velocity law in the event that the
probes are all out of the water.
TOTALIZERS SETTINGS: totalizer settings.
INPUT / OUTPUT SETTINGS: settings of the inputs/outputs.
Summary of Contents for UF 831
Page 5: ...5 NT UF 831 CO GB b March 2014 CHAPTER 1 OVERVIEW...
Page 10: ...10 NT UF 831 CO GB b March 2014 CHAPTER 2 SAFETY INSTRUCTIONS...
Page 14: ...14 NT UF 831 CO GB b March 2014 CHAPTER 3 INSTALLATION AND WIRING...
Page 22: ...22 NT UF 831 CO GB b March 2014 CHAPTER 4 IMPLEMENTING A MEASURING POINT...
Page 26: ...26 NT UF 831 CO GB b March 2014 CHAPTER 5 USING AND CONFIGURING THE UF 831...
Page 59: ...59 NT UF 831 CO GB b March 2014 CHAPTER 6 FUNCTION ENGINE...
Page 61: ...61 NT UF 831 CO GB b March 2014 CHAPTER 7 PC SOFTWARE...
Page 77: ...77 NT UF 831 CO GB b March 2014 Appendix 1 Characteristic echo signals...
Page 80: ...80 NT UF 831 CO GB b March 2014 Appendix 2 Speed of sound in water...