PUMP FOR HYDRAULIC SYSTEMS
-
page 21
of 35
Installation and maintenance manual
3
Put some fitting sealant type Loctite 542 or Loctite
545 on the thread. Fit and screw manually the conical
fittings (3) until they are completely inserted; then
tighten them with a 7/16" open end wrench with a torque
of 17.6 Nm (156 lb ft).
Do not use teflon tape or adhesive tape. Pay attention
to the sealant positioning: if it is inserted into the
system, it could block it and make it unusable.
WARNING
3
3
System fitting
Connection for additional station
System fitting
Connection
for
additional station
5 Position the pump (2) on the dashboard rear
side (5). Then position the gasket (6) as shown in
the picture and the flange (7) with the protective
projecting part towards the dashboard outside.
Fix the pump (2) with the 3 special screws (8)
with a torque of 25 Nm (18.5 lb ft).
CAUTION
Install the pump by positioning the filling hole
(9) towards the top (see the picture) for the right
pump operation and to allow filling and purging
the system completely (see par. 3.11).
Make the shaft pass through the flange equipped
with gasket by preventing the key seat from
damaging the gasket itself.
WARNING
4 By using the proper template supplied with
this manual, make the holes required by the
installation in the suitable position on the
dashboard.
4
2
5
8
6
8
8
7
9