background image

3250 Wiring Diagram 

Page 3

Pre-Installation

Page 4

Components
Pre Installation Check
Installation Procedure

Wire Connectors

Page 5

6 Pin Connector
14 Pin Connector
4 Pin Red Connector
2 Pin White Connector 
Jumper Selection

Installation

Page 6

Basic Installation - Quick start
Auto Tach Learn

Programming

                 

 Page  7-9

Program Overview & 

System Reset

Program Menu 1 (User Settings)
Program Menu 3 (Starter Settings)
Program Menu 4 (Tach Settings)

Operations

Page 10

Transmitter Operation
Timer Mode Settings
Reservation Mode ( Manual Transmission Only)

Additional Operations

Page 11

Transmitter Programming
Service Mode (Valet Mode)

Relay Diagrams

Page 12

If the remote starter has a failed start attempt or if a safety input is activated the Diagnostic Memory will store 
up to four shutdowns in memory. This information can then be accessed to determine the source of the 
shutdown. 

To Enter Diagnostic Mode:
Step 1

 

-

  Turn the ignition on wait two seconds then turn off. Press the Program Button and release.

Step 2 -

  The system will respond with three park light flashes and the horn will honk (optional) the

               same number of times as the events in memory. ( Maximum four events, four honks)

NOTE:

 If the horn does not honk, there are no events in memory. 

Step 3 - 

 Press the Program Button  once to view  the last shut down code. The (optional) Horn will honk once 

to confirm code one. (If the horn does not honk, there are no codes in memory). 

Step 4 -  

The LED’s on the antenna will flash a code corresponding to a shut down trigger. Press the      

Program Button again to check the second code. The horn will honk twice to confirm code two.

Step 5 -  

To 

Clear Diagnostic Memory.

 While in Diagnostic Mode press and hold the Program Button for five 

seconds. The park lights will flash and the horn(optional) will honk once.

    NOTE: 

 Once diagnostic memory has 4 shutdown events in memory, the system will not record         

                 Any further shutdown events until the system memory has been cleared.

PARK LIGHTS

STATUS LED

DIAGNOSTIC CODE

3 Flashes

Series of 3 Flashes

Door Opened “M” Models

3 Slow Flashes

No Flashes

Start Attempt In Service Mode

4 Slow Flashes

Series of 4 Flashes

Not in Reservation Mode “M” units

4 Flashes

Series of 4 Flashes

Hood Pin Grounded (Open)

6 Flashes

Series of 6 Flashes

Brake Pedal Shutdown

7 Flashes

Series of 7 Flashes

Tach Lock-Out

8 Flashes

Series of 8 Flashes

3 Start Attempts with no start

DIAGNOSTICS

2

3

FM ANTENNA WITH DUAL LED’S AND
BUILT-IN VALET SWITCH

11

55

33

22

44

66

Ac

ces

s T

Ju

m

per

s

****

 

These connection’s are only necessary for installation’s on manual transmission vehicles. 

Always install a “M” Series Remote Starter on manual transmission vehicles.

3

 

PI

RED

N

4 PI

 

u

Bl e

S

I

V

W

D

E

 

IE

Jumpers

The jumpers control the output on the white wire from the six pin 
harness. Place the jumpers in the above order to change the output.

Note: The default setting is Second Ignition.

Note: 

Do not use the center pin of this connector to power relay packs. 

Doing so will damage the output. Always use a fused power source when 
installing relays for keyless entry.

Starter

Heater

 Power

Ignition 1

Jumper Selectable

 Power

Note: 

The antenna must be connected before the system will operate.

Summary of Contents for 3250M

Page 1: ...ceived including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part responsible for compliance void the user s authority to operate this devise TECH SUPPORT Western Canada 1 800 279 0636 United States 1 866 698 5872 Eastern Canada Bilingual 1 800 268 0683 E Mail Tech Support support ultrastarters com Check Our Web Site www ultrastart...

Page 2: ...es as the events in memory Maximum four events four honks NOTE If the horn does not honk there are no events in memory Step 3 Press the Program Button once to view the last shut down code The optional Horn will honk once to confirm code one If the horn does not honk there are no codes in memory Step 4 The LED s on the antenna will flash a code corresponding to a shut down trigger Press the Program...

Page 3: ... 4 PI u Bl e SI V W DE IE Jumpers The jumpers control the output on the white wire from the six pin harness Place the jumpers in the above order to change the output Note The default setting is Second Ignition Note Do not use the center pin of this connector to power relay packs Doing so will damage the output Always use a fused power source when installing relays for keyless entry Starter Heater ...

Page 4: ...w more minutes to do the job RIGHT Mounting The Control Module Never mount the module in the engine compartment Select a location under the dash to install the main module Be certain that the module is securely attached and does not obstruct any serviceable areas Do not force or jam the module into tight places instead of mounting The module must be free from all moving parts such as brake and clu...

Page 5: ... Brake Input MUST BE CONNECTED Blue White Tach Tach Signal Input MUST BE CONNECTED ON TACH MODELS Blue Glow Plug Programmable Input DIESEL ONLY Starter Program Mode 6 Pin Power Connector 14 Pin Connector Green Lock Door Lock Output Programmable Menu 1 Setting 3 Red 12vlt Output Low current output for Voltage Inverter Only Blue Door Unlock Door Unlock Output Programmable Menu 1 Setting 3 3 Pin Conn...

Page 6: ...servation Mode to remote start See page 12 for details Your Basic Install Is Complete Your Basic Installation is Now Complete NOTES 1 If the unit does not start check the starter is not in Tach Lock Out or in Program Mode 2 If the vehicle still does not start check all connections and check for factory security Step 2 Plug In The Module Step 3 Auto Tach Learn 1 Make all the required wire connectio...

Page 7: ...ted and one park light flash 7 The Program Menu may be changed at any time by pressing the transmitter buttons as above this allows the installer to change a setting from one menu then quickly jump to another menu and change another setting without re entering the Program Mode 8 Turning off the ignition or 30 seconds of no activity will exit the Program Mode This will be confirmed by 1 long horn h...

Page 8: ...utton Press momentarily to move to next program step or repeat to change selection Press the Program Button 2 times to select setting 2 This will be confirmed by 2 LED flashes Press and hold the Program Button until you receive the appropriate of park light flashes and horn honks Release the Program Button Press momentarily to move to next program step or repeat to change selection Press the Progr...

Page 9: ...s and or horn honks Release the Program Button Press Program Button momentarily to move to next program step or repeat to change selection Press the Program Button 7 times to select setting 7 This will be confirmed by 7 LED flashes Press and hold the Program Button until you receive the appropriate of park light flashes and or horn honks Release the Program Button Press Program Button momentarily ...

Page 10: ...mes if programmed for Safety Start Press and hold for 3 seconds while running to turn off While running with the key press the button to activate Idle Mode Press and Release for Status Check Hold for 3 seconds to enter User Programmable Features Press both buttons for 3 seconds to activate Car Finder Mode Transmitter Operation Reservation Mode Manual Transmission 1 With 2 Pres if the 3 Con 4 Pres ...

Page 11: ...will flash five times and the horn optional will honk five times to confirm that the system is in Service Mode 2 While in Service Mode the remote start functions will be disabled and LED s will be ON steady Door locks and trunk release are still operational DEACTIVATING Service Mode Valet 1 While the ignition is ON press and hold the Program Button for five seconds The park lights will flash two t...

Page 12: ... 87a 30 Lock Un lock Vehicle Lock Unlock Switch To Control Relay or Actuator Green Fused 12V Blue 87 86 85 87a 30 87 86 85 87a 30 Blue Green Lock Un lock Vehicle Lock Unlock Switch To Actuator Fused 12V x x Cut Cut Negative Type Door Locks Positive Type Door Locks 5 Wire Reverse Polarity Type Door Locks 12 ...

Reviews: