www.ultraoptics.com
page 9
Important Notes:
If CYCLE STOP is utilized when the machine is in operation, all lenses will
remain attached to the suction cups and must be removed.
To restart the production cycle, select CYCLE STOP and turn Two Lens
Screen to OFF, then back to ON, and start new production.
Machine Set-up Screen
This screen is used for individual activation of major functions of the Rx.
MENU
– Selecting this button will return to the Main Screen.
COAT ON/OFF
– Selecting this button will turn the coating pump on/off.
DUMP VALVE
– Selecting this button will release pressure build up in high pressure lines
AIR JET
– Selecting this button will activate high pressure airflow through the air jet nozzle
WASH PRIME
– The following sequence must be followed to activate the wash prime:
1. Select VACUUM button
– vacuum will turn on
2. Place lens on suction cup that is above the wash bowl (as shown in Figure 6 on page 7)
3. Select WASH PRIME button
– spindle will lower and high pressure pump will start
4. Select DUMP VALVE button
– this will release pressure and allow to prime wash
5. Select WASH PRIME button
– high pressure pump will stop and spindle will rise
6. Select DUMP VALVE button to shut this valve off
7. Select VACUUM button
– vacuum will turn off and lens will release
VACUUM
– Selecting this button turns on the vacuum for testing
LAMP CYCLE
– Selecting this button will activate the travel of the UV lamp
INDEX
– Selecting this button will index spindles to the next position
HOME DONE
– Indicates spindles are in the home position
MENU
COAT
ON/OFF
DUMP
VALVE
WASH
PRIME
LAMP
CYCLE
HOME
INDEX
INDEX
VACUU
M
AIR
JET
HOME DONE
REMOVE LAMP
90
COVER COATING CYCLE
TIMER IN SECONDS