REV UF-51-940035-20120629
14
UF-51-940035
ENGLISH
The owner/operator is responsible for all periodic
maintenance .
Complete all scheduled maintenance in a timely manner .
Correct any issue before operating the generator .
Never operate a damaged or defective generator .
Tampering with the factory set governor will void
your warranty .
Air Filter
1 . Remove the snap-on cover holding the air filter to
the assembly .
2 . Remove the foam element .
3 . Wash in liquid detergent and water . Squeeze
thoroughly dry in a clean cloth .
4 . Saturate in clean engine oil .
5 . Squeeze in a clean, absorbent cloth to remove all
excess oil .
6 . Place the filter in the assembly .
7 . Reattach the air filter cover and snap in place .
Spark Plugs
1 . Remove the spark plug cable from the spark plug .
2 . Use a 13/16” or 21 mm socket to remove the plug .
3 . Inspect the electrode on the plug . It must be clean and
not worn to produce the spark required for ignition .
4 . Make certain the spark plug gap is 0 .7 - 0 .8mm or
(0 .028 - 0 .031 in .) .
5 . Refer to the spark plug recommendation chart when
replacing the plug .
6 . Carefully thread the plug into the engine .
7 . Use the spark plug tool to firmly install the plug .
8 . Attach the spark plug wire to the plug .
For service or parts assistance, contact our help
line at
1-877-338-0999
NOTE
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual .
NOTE
WARNING
WARNING
Improper maintenance will void your warranty .
WARNING
Oil Cont’d.
0.7 - 0.8 mm
0.028 - 0.031 in.
MAINTENANCE ANd STORAGE
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fill hole .
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking .
NOTE
Engine Maintenance
To prevent accidental starting, remove and ground spark
plug wire before performing any service .
Oil
Change oil when the engine is warm . Refer to the oil
specification to select the proper grade of oil for your
operating environment .
1 . Remove the oil drain plug with a 12 mm socket and
extension .
2 . Allow the oil to drain completely .
3 . Replace the drain plug .
4 . Remove oil fill cap/dipstick to add oil .
5 . Add up to 0 .63 qt . (0 .6 L) of oil and replace oil fill
cap/dipstick .
6 . Dispose of used oil at an approved waste
management facility .