9
REV UF-51-940035-20120629
ENGLISH
UF-51-940035
1 . Place the generator on a flat, level surface .
2 . Remove oil fill cap/dipstick to add oil .
3 . Add up to 0 .63 qt . (0 .6 L) of oil and replace oil fill
cap/dipstick .
4 . Check engine oil level daily and add as needed .
The recommended oil type is 10W-30 4-cycle
automotive oil .
NOTE
The engine is equipped with a low-oil-shutoff and
will stop when the oil level in the crankcase falls
below the threshold level .
CAUTION
Add Engine Oil
DO NOT attempt to crank or start the engine before
it has been properly filled with the recommended
type and amount of oil . Damage to the generator as
a result of failure to follow these instructions will
void your warranty .
CAUTION
ASSEMBLy
Check oil often during the break-in period . Refer to the
Maintenance section for recommended service intervals .
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for
the life of the bearing .
NOTE
Add Engine Oil Cont’d.
Failure to install the spark arrester may result in an
increased risk of fire .
CAUTION
Install the Spark Arrester
1 . Insert the spark arrester screen into the muffler outlet .
2 . Secure the spark arrester by placing the cover plate
over the end of the screen, with the lettering facing
outward .
3 . Secure the cover plate with the two screws and lock
washers provided with the spark arrester kit .
Federal and local laws and administrative
requirements indicate when and where spark
arresters are required . When ordered, spark
arresters are required for operation of this generator
in National Forest lands . In California, this
generator must not be used on any forest- covered
land, brush-covered land, or grass- covered land
unless the engine is equipped with a spark arrester .
NOTE