Configure
Chapter 5: Operating Instructions
Page 5-12
VersaMux-4000 Operation & Installation Guide
Part No. 24001157
Revision C
shows how to access the
System
parameter options from the Front
Panel Interface.
Figure 5-10
Accessing System Sub-Menu Parameter Options
Clk-Ref Parameter
The
Clk-Ref
parameter specifies the source the VersaMux-4000 uses as the
reference for the system timing.
provides descriptions of the
Clk-Ref
options.
Configure
System
Clk-Ref
*
Ext-Clk-Type
*
FP-Lighting
*
ENTER
ENTER
ENTER
Clock-Reference Options
External-Clock-Type Options
Front Panel-Lighting Options
Table 5-2
Clk-Ref Option Descriptions
Option
Description
Ext-1MHz
The VersaMux uses either a 1-MHz Bipolar, a 1-MHz TTL, or a 1-MHz RS-422, signal
from the External Clock Input to generate the System Timing Clock Reference.
Ext-5MHz
The VersaMux uses either a 5-MHz Bipolar, a 5-MHz TTL, or a 5-MHz RS-422, signal
from the External Clock Input to generate the System Timing Clock Reference.
Ext-10MHz
The VersaMux uses either a 10-MHz Bipolar, a 10-MHz TTL, or a 10-MHz RS-422, signal
from the External Clock Input to generate the System Timing Clock Reference.
Aggregate
The VersaMux uses the recovered timing signal from the Aggregate interface to
generate the System Timing Clock Reference.
Port-1
The VersaMux uses the recovered timing signal from the Port 1 interface to generate
the System Timing Clock Reference.
(page 1 of 2)