                       UCDOIM 143 Revision 2 24/03/2021

 

 

Trouble Shooting 

 

 

No POWER LIGHT 

 

 

If green POWER light is not lit, and there is no general power failure to the home, contact your service technician. 

  

 

Low Air Alarm

 red AIR led will flash and audible alarm sound 

 

Press alarm mute button, the alarm will reset and sound again in 24 hours. 

 

Contact your authorised service technician. 

 

The air blower is not operating.  Repairs may need to be carried out, e.g. chamber block kit, piston or blower 

replacement 
  

 

High Water Alarm

 

red WATER led will flash and audible alarm sound 

 

Press alarm mute button, the alarm will reset and sound again in 24 hours. 

 

Especially after mowing or work being carried out in the yard, make the following checks. 

 

Ensure irrigation taps are turned on. 

 

If filter is installed, ensure it is clean. Turn off pump at control box by disconnecting irrigation pump plug, to avoid 

being sprayed with water. Remember to turn pump on when filter is cleaned. 

 

Check sprinkler outlets for any blockages. 

 

Check irrigation line for kinks. 

 

If irrigation line, etc. are OK, phone your authorised service technician. 

 

High water alarm can indicate pump failure, technician to repair or replace. 

  

Bad Odours from System 

 

Wrong products being used, or system overload with overuse. 

 

Check products used.  Especially avoid any disinfectants, bleaches or antiseptics and overuse of

 

laundry 

powders and fabric softeners. 

 

Ensure washing loads are spread over the day. 

 

Bad Odours from Sprinklers 

 

The air blower may not be working to its full capacity, causing low aeration. 

 

Contact your authorised service technician. 

 

Blocked Drainage Lines 

 

Blocked drainage lines from house to the system are plumbing problems. 

 

Check drainage line at inspection opening to clear. 

 

Contact your local plumber or drainer if necessary. 

Electrical 

 

After power black outs or electrical storms it is advisable to check meter box to ensure all circuit breakers are on. 

 

All electrical wiring from system to meter box and to alarm panel is the responsibility of the electrician, and is not 

covered by our warranty. 

 

There is a 15 amp fast blow fuse to protect the pumps.  Should the fuse holder amp be lit, the fuse is open circuit.  

A spare fuse is supplied under the controller enclosure cover, together with photos of correctly terminated cabling 
to the control unit and alarm plate 

 

The alarm panel has three leds.  Under normal operating conditions, the green power led will light.  High water 

alarm will activate the red water led and the audible alarm will sound to attract attention.  If air blower fails the red 
air led will be activated and the audible alarm will sound to attract attention. 

 

Silence alarm by pressing or swiping the MUTE button on the alarm panel. 

 

If problem is not rectified within 24 hours, the led will be activated again with the audible alarm.  Silence alarm by 

pressing or swiping the MUTE button. 

 

Contact your authorised service technician if any alarms occur. 

  

 
 
 
 
 

Summary of Contents for ST8

Page 1: ...0 Owner s Instruction Manual Highland Tanks Pty Ltd trading as Ultra Clear Wastewater Treatment Systems Factory 16 Gantry Place BRAEMAR NSW 2575 Postal PO Box 1158 MITTAGONG NSW 2575 Phone 02 4871 215...

Page 2: ...rvicing Requirements 3 Basic Operating Instructions 3 Trouble Shooting No Power Light Low Air Alarm High Water Alarm Bad Odours from System Bad Odours from Sprinklers Blocked Drainage Lines Electrical...

Page 3: ...ng an aerobic state which reduces the organic load and nitrifies ammonia Sludge Return The settling sludge in the sedimentation chamber is returned to the primary inlet of septic chamber Clarifier Set...

Page 4: ...l ST8 All household wastewater is recycled by treatment using anaerobic and aerobic bacteria with a final disinfectant agent Safe clean treated effluent is automatically irrigated onto lawns and garde...

Page 5: ...wders and fabric softeners Ensure washing loads are spread over the day Bad Odours from Sprinklers The air blower may not be working to its full capacity causing low aeration Contact your authorised s...

Page 6: ...plumbers For safety of service technicians avoid trees or shrubs larger than two metres in close proximity to tanks In accordance with government requirements avoid contact with effluent Spreading of...

Page 7: ...osal Area Irrigation supplied by Ultra Clear is intended as a starter pack only and is not covered by warranty It is the owner s responsibility to install irrigation as required by Council and to main...

Page 8: ...ment Systems or authorised agents to ensure proper maintenance of the system Also subject to installation in accordance with our Plumber s Electrical Installation Manuals STATEMENT OF SERVICE LIFE All...

Page 9: ...Two Service Three Service Four Year 2 Maintenance payment Service One Service Two Service Three Service Four Repairs Year 3 Maintenance payment Service One Service Two Service Three Repairs Year 4 Mai...

Reviews: