Trouble Shooting
•
No POWER LIGHT
•
If green POWER light is not lit, and there is no general power failure to the home, contact your service technician.
•
Low Air Alarm
red AIR led will flash and audible alarm sound
•
Press alarm mute button, the alarm will reset and sound again in 24 hours.
•
Contact your authorised service technician.
•
The air blower is not operating. Repairs may need to be carried out, e.g. chamber block kit, piston or blower
replacement
•
High Water Alarm
red WATER led will flash and audible alarm sound
•
Press alarm mute button, the alarm will reset and sound again in 24 hours.
•
Especially after mowing or work being carried out in the yard, make the following checks.
•
Ensure irrigation taps are turned on.
•
If filter is installed, ensure it is clean. Turn off pump at control box by disconnecting irrigation pump plug, to avoid
being sprayed with water. Remember to turn pump on when filter is cleaned.
•
Check sprinkler outlets for any blockages.
•
Check irrigation line for kinks.
•
If irrigation line, etc. are OK, phone your authorised service technician.
•
High water alarm can indicate pump failure, technician to repair or replace.
Bad Odours from System
Wrong products being used, or system overload with overuse.
Check products used. Especially avoid any disinfectants, bleaches or antiseptics and overuse of
laundry
powders and fabric softeners.
Ensure washing loads are spread over the day.
Bad Odours from Sprinklers
The air blower may not be working to its full capacity, causing low aeration.
Contact your authorised service technician.
Blocked Drainage Lines
Blocked drainage lines from house to the system are plumbing problems.
Check drainage line at inspection opening to clear.
Contact your local plumber or drainer if necessary.
Electrical
•
After power black outs or electrical storms it is advisable to check meter box to ensure all circuit breakers are on.
•
All electrical wiring from system to meter box and to alarm panel is the responsibility of the electrician, and is not
covered by our warranty.
•
There is a 15 amp fast blow fuse to protect the pumps. Should the fuse holder amp be lit, the fuse is open circuit.
A spare fuse is supplied under the controller enclosure cover, together with photos of correctly terminated cabling
to the control unit and alarm plate
•
The alarm panel has three leds. Under normal operating conditions, the green power led will light. High water
alarm will activate the red water led and the audible alarm will sound to attract attention. If air blower fails the red
air led will be activated and the audible alarm will sound to attract attention.
•
Silence alarm by pressing or swiping the MUTE button on the alarm panel.
•
If problem is not rectified within 24 hours, the led will be activated again with the audible alarm. Silence alarm by
pressing or swiping the MUTE button.
•
Contact your authorised service technician if any alarms occur.