8
UAS P-Series Service Manual 574-848-2200
2
7
6
1
3
4
5
2
7
6
1
3
4
5
BOM ID Description
1
LED LIGHT
2
TACT SWITCH PLUG
3
TACT SWITCH
4
PROGRAMMING PORT
5
PORT COVER
6
NUT HX 10-24
7
SCREW 10-24
UAS module overview
Erase ALL
This section explains how to use delete (deny access to) all FOBs that have been programmed to a single
vehicle at the module. Use this process only if NO recognized FOBs are available to erase FOBs.
NOTE: A FOB is NOT required or used to start this process, but at least one FOB will
need to be assign to the vehicle.
1. Stop the vehicle and turn off the engine.
2. Remove overhead panel cover.
3. Remove the TACT switch plug.
4.
Press and hold the TACT switch for (20) seconds. The LED light on the module will turn on and
continue BLINK flash.
5.
After (20) seconds, the LED will glow solid to indicate ALL ERASE mode and all paired FOBs
have been erased. (Do NOT let go of the TACK switch.) Continue to hold the TACK switch for
approximately 1-1/2 minutes. The LED will FLICKER flash once it enters LEARN mode.
6. Release the TACT switch.
7.
Press the button on the FOB to be added. The programming switch lights will DOUBLE flash to
indicate the acknowledged FOB and immediately exit the LEARN mode.
8. Test the FOB to verify that it has been paired correctly.
NOTE: Only one FOB can be programmed using the ERASE ALL process.
9. Reinstall the plug.
10. Additional FOBs can now be added using the
Adding a New FOB
process.