13. BI-WEEKLY SYSTEM TESTING
TEST MODE
Q
When the TEST SENSORS light comes on,
you should test each sensor in the system.
#
The Console must be in Off Mode before
going to Test Mode.
Switch the Console into Test Mode by
entering your secret code and pressing [
TEST
].
Q
When the system is switched to the Test
Mode, the Console will sound a “Gong” and
four “Beeps”.
Q
Placing the system in Test Mode will turn the
TEST SENSORS light off.
Holding down the [
TEST
] button will light all of
the Console’s indicators.
Q
The sensor status lights will flash for each
sensor programmed into the Console.
Go to each sensor and press its test button
or open and close the protected opening.
To test the wireless keypad, press the [
AUTO
]
key.
Q
As each sensor is tested, the sensor status
light for the sensor will stop flashing and
return to showing the current status of the
sensor.
Q
The Console will make a “bing” sound as
each sensor is tested.
Continue testing until there are no flashing
status lights.
NOTE: If the Console is left unattended in
Test Mode, it will automatically switch back
to Off Mode after 3 minutes.
SENSOR LOW BATTERIES
Q
When a sensor’s status light on the Console
blinks, the sensor has a low battery.
NOTE: Don’t confuse a blinking status light
with a flashing status light (flashing light is
faster and indicates alarm memory).
Refer to the figure when replacing
door/window sensor batteries.
22 OF 40
START HERE
TEST
YOUR
SECRET
CODE
DONE
1 GONG &
4 BEEPS
(OPTIONAL)
+
-
+
-
INSTALL TWO
DURACELL
TYPE DL 2032
BATTERIES (+)
SIDE UP
LIFT
WHEN CONSOLE INDICATES A SENSOR
LOW BATTERY, OPEN SENSOR CASE AND
GENTLY LIFT UP END OF BATTERY CLAMP,
SLIDE BATTERIES OUT
REMOVE BATTERIES
FROM THIS END
NOTE: USE OF EXCESSIVE FORCE ON
BATTERY CLAMP WILL RESULT IN DAMAGE
IF NECESSARY
PUSH IN SLOT TO REMOVE
SENSOR FROM MOUNTING PLATE
MANUAL,OWNERS,DF-16K
Linear P/N: 210771 C
Material: 20# White Mead Bond with 60# White Coated Cover
Ink: PMS 554 (Dark Green)
Size: 8.500" x 5.500"
Scale: 1-1