background image

11

(4.5)Install the treatment head

Align in the direction of the arrow as shown below: buckle the treatment head, and then

fix the treatment head with the buckle

Picture 4-1

Picture 4-2

Summary of Contents for Cryolipolysis HF008

Page 1: ...1 User Manual Cryolipolysis HF008 ...

Page 2: ...misalignment from causing side 5 Make sure that the membrane is close to the skin without a lot of air bubbles then place the handle in the middle of the membrane the treatment handle should not touch the skin directly otherwise the skin will be frostbitten Suggest gently press the handle to make it close to the membrane the membrane is close to the skin click the working button of the handle and ...

Page 3: ...a solid undern the low temperature of 2 5 the cryo energy precisely controlled by the non invasive cryo absorption device is delivered to the designated lipolysis site and the fat cells in the designated site are specifically eliminated and when they are subjected to cold to a specific low temperature the liquid triglyceride will con verted into solid then the fat cells death after aging and the d...

Page 4: ...xed point cryolipolysis technique 1 Eliminate Thick Fat 2 Soften the deepen hard thick fat and cellulitis 3 Reduce the intractable of fat cells 4 Tightening 5 Trigger the muscle fiber tension to strengthen the muscle 6 Improve skin relaxation 1 4 Forbidden 1 Pregnant 2 inevitably strong sunshine in daily work 3 people with poor liver 4 people who are allergic to cold easy to freeze hands in winter...

Page 5: ...ature 10 10 Vacuum 10 83Kpa Cold light 570nm 50mw Cooling liquid Pure water Dimension 410mm 397mm 1000mm working temperature 5 40 Operation interface 10 4 touch screen Accessories Host Machine I set Power cable 1pc Water funnel 1 set Support frame for handle 4sets Membrane 10pcs Operation handle 4pcs Treatment heads 4pcs 4pcs 3pcs 1 double chin ...

Page 6: ...ions are as follows Guide 1 vacuum 1 2 3 4 represents the suction of the handle 1 2 3 4 first select Vacuum 1 and then adjust the and on the interface which represent the decrease and increase of the suction 2 The handle has a color touch screen so you can also adjust treatment parameters on the handle 3 If choose button then adjust the and It means that you adjust the treatment temperature of the...

Page 7: ...he upgraded handle material is aluminum alloy and 360 cooling is realized to increase the cooling area and cooling speed and the effect is better the traditional freezer only has two sides of the handle with silicone cooling sheets 2 2 2 handles upgrade 1 The handle is upgraded to replaceable treatment head big handle with 4 pieces heads middle handles with 3 pieces head if you like double chin ha...

Page 8: ...8 the treatment site Now show every body treatment heads ...

Page 9: ... 3 The handle has a color touch screen to set treatment parameters Detection temperature Hand treat cooled temperature Suction strength Treatment time Increase Temperature Vacuum Time Decrease Temperature Vacuum Time preparatory work ...

Page 10: ... operation 2 3 click the work button start work botton on the handle the handle starts to work and sucks the skin 2 4 How to replace the treatment head 4 1 Be careful be sure to gently 4 2 Do not break the buckle 4 3 Then it will look like the picture 4 1 4 4 Then open the top of the buckle as shown in the picture 4 2 Start work button Press the upper end of the buckle first Second push the bottom...

Page 11: ...11 4 5 Install the treatment head Align in the direction of the arrow as shown below buckle the treatment head and then fix the treatment head with the buckle Picture 4 1 Picture 4 2 ...

Page 12: ...to stop the treatment click the work button and hold the treatment handle with hand to prevent the handle from falling down and break 5 The inside of the treatment head must be thoroughly cleaned after treatment Cleaned with a softer tissue 6 Please clean the liquid in the filter on time to prevent the liquid from being sucked into the suction pump and circulating the suction pump Cleaning method ...

Page 13: ... client can shake the treatment area properly during the treatment 6 Remove the treatment head after treatment if there is ice formation please take a towel and ice bag wrap the ice bag with a towel place it on the ice for 15 20 minutes until the ice melted completely To prevent blistering 7 After half an hour of icing massage the frozen area the interval between the first 10 minutes of the massag...

Page 14: ...rosis damage we improve to a safe fat dissolving method that heat the skin first make the blood and fat completely separation and then began to the freeze fat dissolving treatment Q4 What reactivity of the fat cells A4 When fat cells are exposed to precise cooling they trigger a process of natural removal that gradually reduces the thickness of the fat layer And the fat cells will be removed throu...

Page 15: ...aist abdomen Busy life and no time do exercise Stool hoarding gastrointestinal squirms slowly which can not refuse the temptation of delicious food People with non severe obesity who wants to sculpture the fat of waist belly and back fat Q9 What is different from other with other dissolving fat methods A9 Liposuction Benefits one time can take away a lot of fat Notice need general anesthesia whole...

Page 16: ... for pain because of no invasive wound therefore we will not feel painful unlike other liposuction surgery At the very beginning of treatment there will be a little discomfort when the work head absorb fat powerfully but soon will disappear After a while you will feel a little cooling paralysis there is no special feeling During treatment you could play computer read or take a nap Q13 Which group ...

Page 17: ...earby 1 Software out of control replace the controller 2 The display is too tight loosen the four screws of the fixed screen or re move the screen 5 1 4 Very small suction Solution 1 Check the handle whether it is very close to skin 2 Check if the suction pump is working properly 3 Check if there is any leakage in the trachea 5 2Daily maintenance and Care instruction 5 2 1 Maintenance 1 The machin...

Page 18: ... in the machine should be replaced 2 3 months Purified or distilled water 6 Place the machine in a ventilation and dust free room Very important 7 Any non professional is prohibited to use of machine except operator ...