- 14 -
c.Contents of modes and setting values
Mode 00 Setting the measurement kind, time unit, and decimal place
A B C D
0 0
E F G H
0 2 0 0
E→Measurement kind(lower row)
0:B input(speed, rotation, instant)
1:A+B
2:A-B
3:B/A×100
4:(B-A)/A×100
5:B/(A+B)×100
F→Time unit
0:Per hour
1:Per minute
2:Per second
G→Decimal place(of upper row)
0:0
1:0.0
2:0.00
3:0.000
H→Decimal place(of lower row)
0:0
1:0.0
2:0.00
3:0.000
〔E:Measurement kind〕(lower row)
0:B input
1:The sum A+B
2:The difference A-B
3:Absolute ratio B/A×100 When denominator or molecule is zero,
4:Difference ratio (B-A)/A×100 zero is indicated in lower row.
5:Concentration B/(A+B)×100
〔F:Time unit〕
0:The input is shown converted to a rate per hour value.
1:The input is shown converted to a rate per minute value.
2:The input is shown converted to a rate per second value.