background image

Product Manual 

 

 

Page 7 of 19  

2022-10-31 

 

 

OVERVIEW Controls and Connectors 

 

4.1  Front Panel Controls and Indicators 

 

4.2  Rear panel Controls and Connectors 

 
 
 

 

Thermocouple Connector

 

(k type shown others possible)

 

REMOTE

 

Supplied plug 

must be fitted 

with pin 5-15 link

 

RS232

 

Optional for use with 
iTools

 

I ADJUST

 

Current limit potentiometer 
for 100% demand

 

POWER OUTPUT

 

Heater Current

 

MAINS INPUT

 

32A Neutrik connector

 

Protective Earth 

Connection use 4mm

2

 

Summary of Contents for PSU-DC-36-42-C

Page 1: ...PSU DC 36 42 C 36V 42A DC PSU C type thermocouple PSU DC 48 62 K 48V 62A DC PSU K type thermocouple PSU DC 48 62 C 48V 62A DC PSU C type thermocouple PSU DC 60 25 K 60V 25A DC PSU K type thermocouple PSU DC 60 25 C 60V 25A DC PSU C type thermocouple PSU DC 96 31 K 96V 31A DC PSU K type thermocouple PSU DC 96 31 C 96V 31A DC PSU C type thermocouple ...

Page 2: ...uld be aware of the potentials that may exist on any vacuum feedthrough connections Avoid contact with the Thermocouple vacuum feedthroughs especially if they are not grounded It is the responsibility of the user to consider the safety requirements of hazardous materials used with this equipment and the consequence of any leakage however caused Consider possible reactions with materials of constru...

Page 3: ...ectors 7 4 3 Temperature Controller Eurotherm 32h8 8 4 4 Current meter I Adjust 8 4 5 Remote Output Current Voltage Monitor Signals 8 4 6 Communications 9 5 OPERATION QUICK START CONNECT AND ON 10 5 1 Operation Quick Start Manual Temperature control 11 5 2 Operation Quick Start Auto Temperature control 12 5 3 Operation Quick Start Other key settings 13 6 SOFTWARE OPTIONS 14 7 APPENDIX A SPECIFICAT...

Page 4: ... the transport packaging for signs of external damage Unpack the Power Supply and accessories and retain the packaging materials Note Retain the packaging materials for later use The PSU DC XXX must be stored and transported in the original packaging material only Check the package contains all the parts and accessories as shown below Examine the PSU DC XXX for completeness and signs of damage Sho...

Page 5: ...Product Manual Page 5 of 19 2022 10 31 ...

Page 6: ... Rear Panel 6 33x32mm ceramic T6 3A FS1 100 120V Mains Input Rear Panel 6 33x32mm ceramic T12 5A FS2 DC Power Supply Rear Panel 5mmx20mm glass FS3 Output Power Internal bottle fuse D02 gG Warning Disconnect the mains input supply before removing the top cover The cause of any repetitive fuse blowing must be investigated and resolved 3 3 Mains Input Use the supplied Neutrik connector 32 Amp rating ...

Page 7: ... panel Controls and Connectors Thermocouple Connector k type shown others possible REMOTE Supplied plug must be fitted with pin 5 15 link RS232 Optional for use with iTools I ADJUST Current limit potentiometer for 100 demand POWER OUTPUT Heater Current MAINS INPUT 32A Neutrik connector Protective Earth Connection use 4mm 2 ...

Page 8: ...r the unit is normally current limited to just above the maximum recommended this will be noted in the Test Data sheet The unit is current limited to 27 0 Amps as factory default when supplied as a free standing power supply 4 5 Remote Output Current Voltage Monitor Signals The rear panel 15 Way HD connector socket Remote functions are as below Pin 1 Output I Sense ve 1mV Amp Pin 2 No Connection P...

Page 9: ... voltage to any Pin Warning The I and V Sense signals are NOT isolated from the output 4 6 Communications As standard the DC Power Controller is fitted with RS232 communications RS485 is available to special order Connection to rear panel 9 way D Type plug as below Pin 1 Earth Pin 2 HF TX B Pin 3 HE RX A Pin 5 HD Common iTools software is available from Eurotherm at several levels ...

Page 10: ...e to operate either from the front panel controls or remotely Note that rear panel cooling fan will operate as long as the front panel Output switch is ON The Internal DC power module fans will operate according to current demand POWER OFF OUTPUT OFF CONNECT MAINS AND GROUND CONNECT POWER OUTPUT AND THERMOCOUPLE Fit REMOTE plug pin5 15 must be linked POWER ON EUROTHERM BOOT SEQUENCE ...

Page 11: ...lay circled red shows power demand in OUTPUT ON MANUALLY INCREASE CURRENT POWER TO REACH DESIRED TEMPERATURE Refer to equipment manual and test data for maximum and typical operating currents Note there will be a time constant between applied current and temperature rise Press and hold 1s Cycle through modes Auto Manual Off Press LED ON Green Adjust example only shown ...

Page 12: ...ent PID and RR settings If the PSU is supplied with an instrument these have typically been set up SET DEMAND TO 0 DEGREES Note Lower Display circled red shows temperature in degrees C OUTPUT ON INCREASE SET TEMPERATURE Refer to equipment manual and test data for maximum and typical operating currents Note there will be a time constant between applied current and temperature rise Adjust example on...

Page 13: ...n Refer to instrument manual for typical and maximum recommended values Autotune PID 1 Set to Auto Mode see 5 2 2 Set temperature in the range typically required 1 Cycle through 2 Adjust Press and hold Press to select Enter 1 Cycle to ATUNE 2 Set to ON Eurotherm will cycle through settings to optimise tuning ...

Page 14: ...s and downloads Eurother iTools 1 iTools WIZARD free download Allows modification of the Eurotherm module configuration settings such as ramp rate and process time this can be simpler than using the front panel buttons These configurations can be saved and up downloaded Note be cautious of changing settings as it can have unintended consequences It is recommend that the as supplied configuration i...

Page 15: ...f 19 2022 10 31 2 iTools Engineering Studio free download Allows direct control and emulated viewing of the Eurotherm module panel Example screen shots 3 iTools Programmer Editor cost option Refer to Eurotherm for more details ...

Page 16: ...nute Digital Inputs DI1 Standby OFF Default DI2 SP2 Default Others available see Eurotherm Handbook Tuning One shot self tune algorithm Sensor Fail Output OFF Communications RS232 standard RS485 option Environmental Operating Temp 5o C to 40o C Storage 10o C to 70o C Relative Humidity 5 to 85 RH General Electrically conductive pollution to be excluded from the cabinet Not suitable for use above 20...

Page 17: ...wer switch should not be relied upon to provide adequate isolation from the mains supply for servicing or maintenance purposes Use only specified fuses All external cabling must be maintained in good condition and replace if damaged In order to maintain compliance with relevant EU directives only use exact replacement parts when servicing these must have the same specifications and ratings as the ...

Page 18: ... agent 3 We reserve the right to decline to service any equipment we consider is in any way hazardous either by transit damage modification or contamination Repair The following additional terms and conditions apply in the event that the customer elects to use the services of Sabre Controls Ltd workshop on a chargeable basis 1 At its own cost the customer shall dispatch the equipment to the worksh...

Page 19: ...PSU DC MANUAL Rev 3 0 31 10 22 10 Appendix D Wiring Diagram PSU DC 48V 62A ...

Reviews: