2.2.6
Local access via USB
When router is connected to a computer via a USB cable the computer creates a serial COM port. The port number
can be found in the Device Manager. To access the port use can be made of either the OS-integrated terminal
(Hyperterminal) or third-party terminal programs.
With the fist connection of UHP-1100 Router to PC the system will request the device driver. UHP.INF driver is
available on CD with documentation or can be downloaded from our web site. In response to the request for
driver you should refuse from search in Internet and select setting from the specified place where UHP.INF is
saved.
The system will request confirmation for using a non-certified driver. Ignore any system warnings and proceed
with installation. When finished, please check whether a COM port appeared in the Device Manager. If it is
appeared you can start working with the router.
When working with the port from the terminal program the data rate and control parameters can be set to any
value since they are ignored.
W
ITH
USB
OC
PROTOCOL STACK
–
THERE IS A PECULIARITY WHICH LEADS TO
“
HANGING
”
OF THE
USB-
PORT IF IT
CARRIED AN ACTIVE SESSION AND THE CONNECTED DEVICE
(
ROUTER
)
AT THIS MOMENT WAS REBOOTED
.
I
N THIS CASE
YOU HAVE TO LOG OUT FROM THE TERMINAL PROGRAM AND LOG IN AGAIN
.
Y
OU CAN AVOID THIS BY CUTTING OFF THE
SESSION BY
“
HANG
-
UP
”
COMMAND AND ONLY THEN RESTART THE ROUTER USING
RESET
BUTTON OR VIA POWER
SUPPLY CIRCUIT
.
2.2.7
Remote Telnet access
Remote access to the configuration can be performed using Telnet protocol. The connection can be provided to
any of IP addresses that are set on the router. UHP-1100 supports simultaneously only one Telnet session. In order
the hang session does not block access to the device forever in case on non-activity (pressing ENTER key), the
router auto-terminates the session after a certain time of inactivity. The time can be set in the configuration, and
by default it is 10 minutes.
2.2.8
Command Interface
Please refer to the Command Interface manual applicable for the respective version of SW and activated mode of
operation of the UHP router. The Command Interface manuals are available for download and online use on
Romantis website: