Only install the umbrella with no or low wind forces!
Never leave the umbrella with loose fixing or clamp screw.
Open the umbrella:
Aligning the umbrella:
Picture c
• Remove the securing strap and loosen the
membrane.
• Use the winding handle or the electrical drill
with the optional available straight drive win-
der at moderate speed to open the umbrella
until all segments of the membrane are tight
and the stop screw which is fixed on the teles
cope docks on the top of the mast. In case you
are using an electrical drill with the optional
available straight drive winder, do
not
use the
“Drill” position. Use the torque limiter of the
drill to prevent damage.
• When opening and closing the umbrella the
last 3-4 rotations should be operated manual
with the winding handle (this is when the stop
screw on the telescope approaches the top of
the umbrella mast).
• When the umbrella is half open remove the
blue foam parts which were attached to pro-
tect during transportation.
(Picture c)
• Align the umbrella with a spirit level or with
vertical lines of the surroundings (e.g.buil-
dings, lamp posts, etc.). Turn the umbrella
within the upper sleeve till you have reached
the desired position (the fixing and clamping
screw need to be loose to do so).
• Once aligned, the clamping- and fixing
screw must be tightened.
Drill force: clamping screw 40-50 N m and
fixing screw approx. 10 N m
21